# Chassis by IPMI
|
||
|
|
||
|
## Overview
|
||
|
|
||
|
Template for monitoring servers with BMC over IPMI that work without any external scripts.
|
||
|
All metrics are collected at once, thanks to Zabbix's bulk data collection.
|
||
|
It collects metrics by polling BMC remotely using an IPMI agent.
|
||
|
|
||
|
###Known Issues
|
||
|
|
||
|
- Description: If the BMC has a sensor with an empty threshold value, we get the LLD error "Cannot create trigger...".
|
||
|
|
||
|
|
||
|
## Requirements
|
||
|
|
||
|
Zabbix version: 7.0 and higher.
|
||
|
|
||
|
## Tested versions
|
||
|
|
||
|
This template has been tested on:
|
||
|
- HP iLO, DELL DRAC, IBM RSA
|
||
|
|
||
|
## Configuration
|
||
|
|
||
|
> Zabbix should be configured according to the instructions in the [Templates out of the box](https://www.zabbix.com/documentation/7.0/manual/config/templates_out_of_the_box) section.
|
||
|
|
||
|
## Setup
|
||
|
|
||
|
You can set {$IPMI.USER} and {$IPMI.PASSWORD} macros in the template for using on the host level.
|
||
|
|
||
|
|
||
|
### Macros used
|
||
|
|
||
|
|Name|Description|Default|
|
||
|
|----|-----------|-------|
|
||
|
|{$IPMI.USER}|<p>This macro is used for access to BMC. It can be overridden on the host or linked template level.</p>||
|
||
|
|{$IPMI.PASSWORD}|<p>This macro is used for access to BMC. It can be overridden on the host or linked template level.</p>||
|
||
|
|{$IPMI.SENSOR_TYPE.MATCHES}|<p>This macro is used in sensors discovery. It can be overridden on the host or linked template level.</p>|`.*`|
|
||
|
|{$IPMI.SENSOR_TYPE.NOT_MATCHES}|<p>This macro is used in sensors discovery. It can be overridden on the host or linked template level.</p>|`invalid`|
|
||
|
|
||
|
### Items
|
||
|
|
||
|
|Name|Description|Type|Key and additional info|
|
||
|
|----|-----------|----|-----------------------|
|
||
|
|IPMI: Get IPMI sensors|<p>The master item that receives all sensors with values for LLD and dependent elements from BMC.</p>|IPMI agent|ipmi.get|
|
||
|
|
||
|
### LLD rule Discrete sensors discovery
|
||
|
|
||
|
|Name|Description|Type|Key and additional info|
|
||
|
|----|-----------|----|-----------------------|
|
||
|
|Discrete sensors discovery|<p>Discovery of the discrete IPMI sensors.</p>|Dependent item|ipmi.discrete.discovery|
|
||
|
|
||
|
### Item prototypes for Discrete sensors discovery
|
||
|
|
||
|
|Name|Description|Type|Key and additional info|
|
||
|
|----|-----------|----|-----------------------|
|
||
|
|IPMI: {#SENSOR_ID}|<p>It is a state of the discrete IPMI sensor.</p>|Dependent item|ipmi.state_text[{#SENSOR_ID}]<p>**Preprocessing**</p><ul><li><p>JSON Path: `$.[?(@.id=='{#SENSOR_ID}')].state.text.first()`</p></li><li><p>Discard unchanged with heartbeat: `1d`</p></li></ul>|
|
||
|
|
||
|
### Trigger prototypes for Discrete sensors discovery
|
||
|
|
||
|
|Name|Description|Expression|Severity|Dependencies and additional info|
|
||
|
|----|-----------|----------|--------|--------------------------------|
|
||
|
|IPMI: {#SENSOR_ID} value has changed|<p>The trigger is informing about changes in a state of the discrete IPMI sensor. A problem generated by this trigger can be manually closed.</p>|`last(/Chassis by IPMI/ipmi.state_text[{#SENSOR_ID}],#1)<>last(/Chassis by IPMI/ipmi.state_text[{#SENSOR_ID}],#2)`|Info|**Manual close**: Yes|
|
||
|
|
||
|
### LLD rule Threshold sensors discovery
|
||
|
|
||
|
|Name|Description|Type|Key and additional info|
|
||
|
|----|-----------|----|-----------------------|
|
||
|
|Threshold sensors discovery|<p>Discovery of the threshold IPMI sensors.</p>|Dependent item|ipmi.sensors.discovery|
|
||
|
|
||
|
### Item prototypes for Threshold sensors discovery
|
||
|
|
||
|
|Name|Description|Type|Key and additional info|
|
||
|
|----|-----------|----|-----------------------|
|
||
|
|IPMI: {#SENSOR_ID}, {#SENSOR_UNIT}|<p>It is a state of the threshold IPMI sensor.</p>|Dependent item|ipmi.value[{#SENSOR_ID}]<p>**Preprocessing**</p><ul><li><p>JSON Path: `$.[?(@.id=='{#SENSOR_ID}')].value.first()`</p></li><li><p>Discard unchanged with heartbeat: `1h`</p></li></ul>|
|
||
|
|
||
|
### Trigger prototypes for Threshold sensors discovery
|
||
|
|
||
|
|Name|Description|Expression|Severity|Dependencies and additional info|
|
||
|
|----|-----------|----------|--------|--------------------------------|
|
||
|
|IPMI: {#SENSOR_ID} value is below non-critical low|<p>The trigger is informing that a value less than the lower non-critical threshold has been reached.</p>|`min(/Chassis by IPMI/ipmi.value[{#SENSOR_ID}],5m)<{#SENSOR_LO_WARN}`|Warning|**Depends on**:<br><ul><li>IPMI: {#SENSOR_ID} value is below critical low</li><li>IPMI: {#SENSOR_ID} value is below non-recoverable low</li></ul>|
|
||
|
|IPMI: {#SENSOR_ID} value is below critical low|<p>The trigger is informing that a value less than the lower critical threshold has been reached.</p>|`min(/Chassis by IPMI/ipmi.value[{#SENSOR_ID}],5m)<{#SENSOR_LO_CRIT}`|High|**Depends on**:<br><ul><li>IPMI: {#SENSOR_ID} value is below non-recoverable low</li></ul>|
|
||
|
|IPMI: {#SENSOR_ID} value is below non-recoverable low|<p>The trigger is informing that a value less than the lower non-recoverable threshold has been reached.</p>|`min(/Chassis by IPMI/ipmi.value[{#SENSOR_ID}],5m)<{#SENSOR_LO_DISAST}`|Disaster||
|
||
|
|IPMI: {#SENSOR_ID} value is above non-critical high|<p>The trigger is informing that a value higher than the upper non-critical threshold has been reached.</p>|`min(/Chassis by IPMI/ipmi.value[{#SENSOR_ID}],5m)>{#SENSOR_HI_WARN}`|Warning|**Depends on**:<br><ul><li>IPMI: {#SENSOR_ID} value is above critical high</li><li>IPMI: {#SENSOR_ID} value is above non-recoverable high</li></ul>|
|
||
|
|IPMI: {#SENSOR_ID} value is above critical high|<p>The trigger is informing that a value higher than the upper critical threshold has been reached.</p>|`min(/Chassis by IPMI/ipmi.value[{#SENSOR_ID}],5m)>{#SENSOR_HI_CRIT}`|High|**Depends on**:<br><ul><li>IPMI: {#SENSOR_ID} value is above non-recoverable high</li></ul>|
|
||
|
|IPMI: {#SENSOR_ID} value is above non-recoverable high|<p>The trigger is informing that a value higher than the upper non-recoverable threshold has been reached.</p>|`min(/Chassis by IPMI/ipmi.value[{#SENSOR_ID}],5m)>{#SENSOR_HI_DISAST}`|Disaster||
|
||
|
|
||
|
## Feedback
|
||
|
|
||
|
Please report any issues with the template at [`https://support.zabbix.com`](https://support.zabbix.com)
|
||
|
|
||
|
You can also provide feedback, discuss the template, or ask for help at [`ZABBIX forums`](https://www.zabbix.com/forum/zabbix-suggestions-and-feedback)
|
||
|
|