You can not select more than 25 topics Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.
yzl 93958d0fb0
zabbix6.0
1 year ago
..
README.md zabbix6.0 1 year ago
template_server_cisco_ucs_snmp.yaml zabbix6.0 1 year ago

README.md

Cisco UCS by SNMP

Overview

Template for Cisco UCS monitoring via Integrated Management Controller

Requirements

Zabbix version: 7.0 and higher.

Tested versions

This template has been tested on:

  • Cisco UCS C240 M4SX

Configuration

Zabbix should be configured according to the instructions in the Templates out of the box section.

Setup

Refer to the vendor documentation.

Macros used

Name Description Default
{$PSU_CRIT_STATUS:"inoperable"} 2
{$PSU_WARN_STATUS:"degraded"} 3
{$FAN_CRIT_STATUS:"inoperable"} 2
{$FAN_WARN_STATUS:"degraded"} 3
{$TEMP_CRIT:"Ambient"} 35
{$TEMP_WARN:"Ambient"} 30
{$DISK_ARRAY_CACHE_BATTERY_OK_STATUS} 1
{$DISK_ARRAY_CACHE_BATTERY_CRIT_STATUS} 2
{$DISK_ARRAY_CRIT_STATUS:"inoperable"} 2
{$DISK_ARRAY_WARN_STATUS:"degraded"} 3
{$DISK_ARRAY_OK_STATUS:"operable"} 1
{$DISK_FAIL_STATUS:"failed"} 9
{$DISK_CRIT_STATUS:"predictiveFailure"} 11
{$DISK_CRIT_STATUS:"bad"} 16
{$VDISK_OK_STATUS:"equipped"} 10
{$HEALTH_CRIT_STATUS:"computeFailed"} 30
{$HEALTH_CRIT_STATUS:"configFailure"} 33
{$HEALTH_CRIT_STATUS:"unconfigFailure"} 34
{$HEALTH_CRIT_STATUS:"inoperable"} 60
{$HEALTH_WARN_STATUS:"testFailed"} 35
{$HEALTH_WARN_STATUS:"thermalProblem"} 60
{$HEALTH_WARN_STATUS:"powerProblem"} 62
{$HEALTH_WARN_STATUS:"voltageProblem"} 62
{$HEALTH_WARN_STATUS:"diagnosticsFailed"} 204
{$TEMP_CRIT} 60
{$TEMP_CRIT_LOW} 5
{$TEMP_WARN} 50
{$SNMP.TIMEOUT} 5m
{$ICMP_LOSS_WARN} 20
{$ICMP_RESPONSE_TIME_WARN} 0.15

Items

Name Description Type Key and additional info
Cisco UCS: Uptime (network)

MIB: SNMPv2-MIB

The time (in hundredths of a second) since the network management portion of the system was last re-initialized.

SNMP agent system.net.uptime[sysUpTime.0]

Preprocessing

  • Custom multiplier: 0.01

Cisco UCS: Uptime (hardware)

MIB: HOST-RESOURCES-MIB

The amount of time since this host was last initialized. Note that this is different from sysUpTime in the SNMPv2-MIB [RFC1907] because sysUpTime is the uptime of the network management portion of the system.

SNMP agent system.hw.uptime[hrSystemUptime.0]

Preprocessing

  • Check for not supported value

    Custom on fail: Set value to: 0

  • Custom multiplier: 0.01

Cisco UCS: SNMP traps (fallback)

The item is used to collect all SNMP traps unmatched by other snmptrap items

SNMP trap snmptrap.fallback
Cisco UCS: System location

MIB: SNMPv2-MIB

The physical location of this node (e.g., `telephone closet, 3rd floor'). If the location is unknown, the value is the zero-length string.

SNMP agent system.location[sysLocation.0]

Preprocessing

  • Discard unchanged with heartbeat: 12h

Cisco UCS: System contact details

MIB: SNMPv2-MIB

The textual identification of the contact person for this managed node, together with information on how to contact this person. If no contact information is known, the value is the zero-length string.

SNMP agent system.contact[sysContact.0]

Preprocessing

  • Discard unchanged with heartbeat: 12h

Cisco UCS: System object ID

MIB: SNMPv2-MIB

The vendor's authoritative identification of the network management subsystem contained in the entity. This value is allocated within the SMI enterprises subtree (1.3.6.1.4.1) and provides an easy and unambiguous means for determiningwhat kind of box' is being managed. For example, if vendorFlintstones, Inc.' was assigned the subtree1.3.6.1.4.1.4242, it could assign the identifier 1.3.6.1.4.1.4242.1.1 to its `Fred Router'.

SNMP agent system.objectid[sysObjectID.0]

Preprocessing

  • Discard unchanged with heartbeat: 12h

Cisco UCS: System name

MIB: SNMPv2-MIB

An administratively-assigned name for this managed node.By convention, this is the node's fully-qualified domain name. If the name is unknown, the value is the zero-length string.

SNMP agent system.name

Preprocessing

  • Discard unchanged with heartbeat: 12h

Cisco UCS: System description

MIB: SNMPv2-MIB

A textual description of the entity. This value should

include the full name and version identification of the system's hardware type, software operating-system, and

networking software.

SNMP agent system.descr[sysDescr.0]

Preprocessing

  • Discard unchanged with heartbeat: 12h

Cisco UCS: SNMP agent availability

Availability of SNMP checks on the host. The value of this item corresponds to availability icons in the host list.

Possible value:

0 - not available

1 - available

2 - unknown

Zabbix internal zabbix[host,snmp,available]
Cisco UCS: ICMP ping Simple check icmpping
Cisco UCS: ICMP loss Simple check icmppingloss
Cisco UCS: ICMP response time Simple check icmppingsec

Triggers

Name Description Expression Severity Dependencies and additional info
Cisco UCS: Host has been restarted

Uptime is less than 10 minutes.

(last(/Cisco UCS by SNMP/system.hw.uptime[hrSystemUptime.0])>0 and last(/Cisco UCS by SNMP/system.hw.uptime[hrSystemUptime.0])<10m) or (last(/Cisco UCS by SNMP/system.hw.uptime[hrSystemUptime.0])=0 and last(/Cisco UCS by SNMP/system.net.uptime[sysUpTime.0])<10m) Warning Manual close: Yes
Depends on:
  • Cisco UCS: No SNMP data collection
Cisco UCS: System name has changed

The name of the system has changed. Acknowledge to close the problem manually.

last(/Cisco UCS by SNMP/system.name,#1)<>last(/Cisco UCS by SNMP/system.name,#2) and length(last(/Cisco UCS by SNMP/system.name))>0 Info Manual close: Yes
Cisco UCS: No SNMP data collection

SNMP is not available for polling. Please check device connectivity and SNMP settings.

max(/Cisco UCS by SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0 Warning Depends on:
  • Cisco UCS: Unavailable by ICMP ping
Cisco UCS: Unavailable by ICMP ping

Last three attempts returned timeout. Please check device connectivity.

max(/Cisco UCS by SNMP/icmpping,#3)=0 High
Cisco UCS: High ICMP ping loss min(/Cisco UCS by SNMP/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/Cisco UCS by SNMP/icmppingloss,5m)<100 Warning Depends on:
  • Cisco UCS: Unavailable by ICMP ping
Cisco UCS: High ICMP ping response time avg(/Cisco UCS by SNMP/icmppingsec,5m)>{$ICMP_RESPONSE_TIME_WARN} Warning Depends on:
  • Cisco UCS: High ICMP ping loss
  • Cisco UCS: Unavailable by ICMP ping

LLD rule Temperature Discovery

Name Description Type Key and additional info
Temperature Discovery SNMP agent temp.discovery

Item prototypes for Temperature Discovery

Name Description Type Key and additional info
{#SENSOR_LOCATION}.Ambient: Temperature

MIB: CISCO-UNIFIED-COMPUTING-COMPUTE-MIB

Temperature readings of testpoint: {#SENSOR_LOCATION}.Ambient

SNMP agent sensor.temp.value[cucsComputeRackUnitMbTempStatsAmbientTemp.{#SNMPINDEX}]
{#SENSOR_LOCATION}.Front: Temperature

MIB: CISCO-UNIFIED-COMPUTING-COMPUTE-MIB

Cisco UCS compute:RackUnitMbTempStats:frontTemp managed object property

SNMP agent sensor.temp.value[cucsComputeRackUnitMbTempStatsFrontTemp.{#SNMPINDEX}]
{#SENSOR_LOCATION}.Rear: Temperature

MIB: CISCO-UNIFIED-COMPUTING-COMPUTE-MIB

Cisco UCS compute:RackUnitMbTempStats:rearTemp managed object property

SNMP agent sensor.temp.value[cucsComputeRackUnitMbTempStatsRearTemp.{#SNMPINDEX}]
{#SENSOR_LOCATION}.IOH: Temperature

MIB: CISCO-UNIFIED-COMPUTING-COMPUTE-MIB

Cisco UCS compute:RackUnitMbTempStats:ioh1Temp managed object property

SNMP agent sensor.temp.value[cucsComputeRackUnitMbTempSltatsIoh1Temp.{#SNMPINDEX}]

Trigger prototypes for Temperature Discovery

Name Description Expression Severity Dependencies and additional info
{#SENSOR_LOCATION}.Ambient: Temperature is above warning threshold

This trigger uses temperature sensor values as well as temperature sensor status if available

avg(/Cisco UCS by SNMP/sensor.temp.value[cucsComputeRackUnitMbTempStatsAmbientTemp.{#SNMPINDEX}],5m)>{$TEMP_WARN:"Ambient"} Warning Depends on:
  • {#SENSOR_LOCATION}.Ambient: Temperature is above critical threshold
{#SENSOR_LOCATION}.Ambient: Temperature is above critical threshold

This trigger uses temperature sensor values as well as temperature sensor status if available

avg(/Cisco UCS by SNMP/sensor.temp.value[cucsComputeRackUnitMbTempStatsAmbientTemp.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"Ambient"} High
{#SENSOR_LOCATION}.Ambient: Temperature is too low avg(/Cisco UCS by SNMP/sensor.temp.value[cucsComputeRackUnitMbTempStatsAmbientTemp.{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:"Ambient"} Average
{#SENSOR_LOCATION}.Front: Temperature is above warning threshold

This trigger uses temperature sensor values as well as temperature sensor status if available

avg(/Cisco UCS by SNMP/sensor.temp.value[cucsComputeRackUnitMbTempStatsFrontTemp.{#SNMPINDEX}],5m)>{$TEMP_WARN:"Ambient"} Warning Depends on:
  • {#SENSOR_LOCATION}.Front: Temperature is above critical threshold
{#SENSOR_LOCATION}.Front: Temperature is above critical threshold

This trigger uses temperature sensor values as well as temperature sensor status if available

avg(/Cisco UCS by SNMP/sensor.temp.value[cucsComputeRackUnitMbTempStatsFrontTemp.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"Ambient"} High
{#SENSOR_LOCATION}.Front: Temperature is too low avg(/Cisco UCS by SNMP/sensor.temp.value[cucsComputeRackUnitMbTempStatsFrontTemp.{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:"Ambient"} Average
{#SENSOR_LOCATION}.Rear: Temperature is above warning threshold

This trigger uses temperature sensor values as well as temperature sensor status if available

avg(/Cisco UCS by SNMP/sensor.temp.value[cucsComputeRackUnitMbTempStatsRearTemp.{#SNMPINDEX}],5m)>{$TEMP_WARN:"Ambient"} Warning Depends on:
  • {#SENSOR_LOCATION}.Rear: Temperature is above critical threshold
{#SENSOR_LOCATION}.Rear: Temperature is above critical threshold

This trigger uses temperature sensor values as well as temperature sensor status if available

avg(/Cisco UCS by SNMP/sensor.temp.value[cucsComputeRackUnitMbTempStatsRearTemp.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"Ambient"} High
{#SENSOR_LOCATION}.Rear: Temperature is too low avg(/Cisco UCS by SNMP/sensor.temp.value[cucsComputeRackUnitMbTempStatsRearTemp.{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:"Ambient"} Average
{#SENSOR_LOCATION}.IOH: Temperature is above warning threshold

This trigger uses temperature sensor values as well as temperature sensor status if available

avg(/Cisco UCS by SNMP/sensor.temp.value[cucsComputeRackUnitMbTempSltatsIoh1Temp.{#SNMPINDEX}],5m)>{$TEMP_WARN:"Ambient"} Warning Depends on:
  • {#SENSOR_LOCATION}.IOH: Temperature is above critical threshold
{#SENSOR_LOCATION}.IOH: Temperature is above critical threshold

This trigger uses temperature sensor values as well as temperature sensor status if available

avg(/Cisco UCS by SNMP/sensor.temp.value[cucsComputeRackUnitMbTempSltatsIoh1Temp.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"Ambient"} High
{#SENSOR_LOCATION}.IOH: Temperature is too low avg(/Cisco UCS by SNMP/sensor.temp.value[cucsComputeRackUnitMbTempSltatsIoh1Temp.{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:"Ambient"} Average

LLD rule Temperature CPU Discovery

Name Description Type Key and additional info
Temperature CPU Discovery SNMP agent temp.cpu.discovery

Item prototypes for Temperature CPU Discovery

Name Description Type Key and additional info
{#SENSOR_LOCATION}: Temperature

MIB: CISCO-UNIFIED-COMPUTING-PROCESSOR-MIB

Cisco UCS processor:EnvStats:temperature managed object property

SNMP agent sensor.temp.value[cucsProcessorEnvStatsTemperature.{#SNMPINDEX}]

Trigger prototypes for Temperature CPU Discovery

Name Description Expression Severity Dependencies and additional info
{#SENSOR_LOCATION}: Temperature is above warning threshold

This trigger uses temperature sensor values as well as temperature sensor status if available

avg(/Cisco UCS by SNMP/sensor.temp.value[cucsProcessorEnvStatsTemperature.{#SNMPINDEX}],5m)>{$TEMP_WARN:"CPU"} Warning Depends on:
  • {#SENSOR_LOCATION}: Temperature is above critical threshold
{#SENSOR_LOCATION}: Temperature is above critical threshold

This trigger uses temperature sensor values as well as temperature sensor status if available

avg(/Cisco UCS by SNMP/sensor.temp.value[cucsProcessorEnvStatsTemperature.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"CPU"} High
{#SENSOR_LOCATION}: Temperature is too low avg(/Cisco UCS by SNMP/sensor.temp.value[cucsProcessorEnvStatsTemperature.{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:"CPU"} Average

LLD rule PSU Discovery

Name Description Type Key and additional info
PSU Discovery SNMP agent psu.discovery

Item prototypes for PSU Discovery

Name Description Type Key and additional info
{#PSU_LOCATION}: Power supply status

MIB: CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB

Cisco UCS equipment:Psu:operState managed object property

SNMP agent sensor.psu.status[cucsEquipmentPsuOperState.{#SNMPINDEX}]

Trigger prototypes for PSU Discovery

Name Description Expression Severity Dependencies and additional info
{#PSU_LOCATION}: Power supply is in critical state

Please check the power supply unit for errors

count(/Cisco UCS by SNMP/sensor.psu.status[cucsEquipmentPsuOperState.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS:\"inoperable\"}")=1 Average
{#PSU_LOCATION}: Power supply is in warning state

Please check the power supply unit for errors

count(/Cisco UCS by SNMP/sensor.psu.status[cucsEquipmentPsuOperState.{#SNMPINDEX}],#1,"eq","{$PSU_WARN_STATUS:\"degraded\"}")=1 Warning Depends on:
  • {#PSU_LOCATION}: Power supply is in critical state

LLD rule Unit Discovery

Name Description Type Key and additional info
Unit Discovery SNMP agent unit.discovery

Item prototypes for Unit Discovery

Name Description Type Key and additional info
{#UNIT_LOCATION}: Overall system health status

MIB: CISCO-UNIFIED-COMPUTING-COMPUTE-MIB

Cisco UCS compute:RackUnit:operState managed object property

SNMP agent system.status[cucsComputeRackUnitOperState.{#SNMPINDEX}]
{#UNIT_LOCATION}: Hardware model name

MIB: CISCO-UNIFIED-COMPUTING-COMPUTE-MIB

Cisco UCS compute:RackUnit:model managed object property

SNMP agent system.hw.model[cucsComputeRackUnitModel.{#SNMPINDEX}]

Preprocessing

  • Discard unchanged with heartbeat: 1d

{#UNIT_LOCATION}: Hardware serial number

MIB: CISCO-UNIFIED-COMPUTING-COMPUTE-MIB

Cisco UCS compute:RackUnit:serial managed object property

SNMP agent system.hw.serialnumber[cucsComputeRackUnitSerial.{#SNMPINDEX}]

Preprocessing

  • Discard unchanged with heartbeat: 1d

Trigger prototypes for Unit Discovery

Name Description Expression Severity Dependencies and additional info
{#UNIT_LOCATION}: System status is in critical state

Please check the device for errors

count(/Cisco UCS by SNMP/system.status[cucsComputeRackUnitOperState.{#SNMPINDEX}],#1,"eq","{$HEALTH_CRIT_STATUS:\"computeFailed\"}")=1 or count(/Cisco UCS by SNMP/system.status[cucsComputeRackUnitOperState.{#SNMPINDEX}],#1,"eq","{$HEALTH_CRIT_STATUS:\"configFailure\"}")=1 or count(/Cisco UCS by SNMP/system.status[cucsComputeRackUnitOperState.{#SNMPINDEX}],#1,"eq","{$HEALTH_CRIT_STATUS:\"unconfigFailure\"}")=1 or count(/Cisco UCS by SNMP/system.status[cucsComputeRackUnitOperState.{#SNMPINDEX}],#1,"eq","{$HEALTH_CRIT_STATUS:\"inoperable\"}")=1 High
{#UNIT_LOCATION}: System status is in warning state

Please check the device for warnings

count(/Cisco UCS by SNMP/system.status[cucsComputeRackUnitOperState.{#SNMPINDEX}],#1,"eq","{$HEALTH_WARN_STATUS:\"testFailed\"}")=1 or count(/Cisco UCS by SNMP/system.status[cucsComputeRackUnitOperState.{#SNMPINDEX}],#1,"eq","{$HEALTH_WARN_STATUS:\"thermalProblem\"}")=1 or count(/Cisco UCS by SNMP/system.status[cucsComputeRackUnitOperState.{#SNMPINDEX}],#1,"eq","{$HEALTH_WARN_STATUS:\"powerProblem\"}")=1 or count(/Cisco UCS by SNMP/system.status[cucsComputeRackUnitOperState.{#SNMPINDEX}],#1,"eq","{$HEALTH_WARN_STATUS:\"voltageProblem\"}")=1 or count(/Cisco UCS by SNMP/system.status[cucsComputeRackUnitOperState.{#SNMPINDEX}],#1,"eq","{$HEALTH_WARN_STATUS:\"diagnosticsFailed\"}")=1 Warning Depends on:
  • {#UNIT_LOCATION}: System status is in critical state
{#UNIT_LOCATION}: Device has been replaced

Device serial number has changed. Acknowledge to close the problem manually.

last(/Cisco UCS by SNMP/system.hw.serialnumber[cucsComputeRackUnitSerial.{#SNMPINDEX}],#1)<>last(/Cisco UCS by SNMP/system.hw.serialnumber[cucsComputeRackUnitSerial.{#SNMPINDEX}],#2) and length(last(/Cisco UCS by SNMP/system.hw.serialnumber[cucsComputeRackUnitSerial.{#SNMPINDEX}]))>0 Info Manual close: Yes

LLD rule FAN Discovery

Name Description Type Key and additional info
FAN Discovery SNMP agent fan.discovery

Item prototypes for FAN Discovery

Name Description Type Key and additional info
{#FAN_LOCATION}: Fan status

MIB: CISCO-UNIFIED-COMPUTING-EQUIPMENT-MIB

Cisco UCS equipment:Fan:operState managed object property

SNMP agent sensor.fan.status[cucsEquipmentFanOperState.{#SNMPINDEX}]

Trigger prototypes for FAN Discovery

Name Description Expression Severity Dependencies and additional info
{#FAN_LOCATION}: Fan is in warning state

Please check the fan unit

count(/Cisco UCS by SNMP/sensor.fan.status[cucsEquipmentFanOperState.{#SNMPINDEX}],#1,"eq","{$FAN_WARN_STATUS:\"degraded\"}")=1 Warning Depends on:
  • {#FAN_LOCATION}: Fan is in critical state
{#FAN_LOCATION}: Fan is in critical state

Please check the fan unit

count(/Cisco UCS by SNMP/sensor.fan.status[cucsEquipmentFanOperState.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS:\"inoperable\"}")=1 Average

LLD rule Physical Disk Discovery

Name Description Type Key and additional info
Physical Disk Discovery

Scanning table of physical drive entries CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageLocalDiskTable.

SNMP agent physicalDisk.discovery

Item prototypes for Physical Disk Discovery

Name Description Type Key and additional info
{#DISK_LOCATION}: Physical disk status

MIB: CISCO-UNIFIED-COMPUTING-STORAGE-MIB

Cisco UCS storage:LocalDisk:diskState managed object property.

SNMP agent system.hw.physicaldisk.status[cucsStorageLocalDiskDiskState.{#SNMPINDEX}]
{#DISK_LOCATION}: Physical disk model name

MIB: CISCO-UNIFIED-COMPUTING-STORAGE-MIB

Cisco UCS storage:LocalDisk:serial managed object property. Actually returns part number code

SNMP agent system.hw.physicaldisk.model[cucsStorageLocalDiskSerial.{#SNMPINDEX}]
{#DISK_LOCATION}: Physical disk media type

MIB: CISCO-UNIFIED-COMPUTING-STORAGE-MIB

Cisco UCS storage:LocalDisk:model managed object property. Actually returns 'HDD' or 'SSD'

SNMP agent system.hw.physicaldisk.media_type[cucsStorageLocalDiskModel.{#SNMPINDEX}]
{#DISK_LOCATION}: Disk size

MIB: CISCO-UNIFIED-COMPUTING-STORAGE-MIB

Cisco UCS storage:LocalDisk:size managed object property. In MB.

SNMP agent system.hw.physicaldisk.size[cucsStorageLocalDiskSize.{#SNMPINDEX}]

Preprocessing

  • Custom multiplier: 1048576

Trigger prototypes for Physical Disk Discovery

Name Description Expression Severity Dependencies and additional info
{#DISK_LOCATION}: Physical disk failed

Please check physical disk for warnings or errors

count(/Cisco UCS by SNMP/system.hw.physicaldisk.status[cucsStorageLocalDiskDiskState.{#SNMPINDEX}],#1,"eq","{$DISK_FAIL_STATUS:\"failed\"}")=1 High
{#DISK_LOCATION}: Physical disk error

Please check physical disk for warnings or errors

count(/Cisco UCS by SNMP/system.hw.physicaldisk.status[cucsStorageLocalDiskDiskState.{#SNMPINDEX}],#1,"eq","{$DISK_CRIT_STATUS:\"bad\"}")=1 or count(/Cisco UCS by SNMP/system.hw.physicaldisk.status[cucsStorageLocalDiskDiskState.{#SNMPINDEX}],#1,"eq","{$DISK_CRIT_STATUS:\"predictiveFailure\"}")=1 Average Depends on:
  • {#DISK_LOCATION}: Physical disk failed

LLD rule Virtual Disk Discovery

Name Description Type Key and additional info
Virtual Disk Discovery

CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageLocalLunTable

SNMP agent virtualdisk.discovery

Item prototypes for Virtual Disk Discovery

Name Description Type Key and additional info
{#VDISK_LOCATION}: Status

MIB: CISCO-UNIFIED-COMPUTING-STORAGE-MIB

Cisco UCS storage:LocalLun:presence managed object property

SNMP agent system.hw.virtualdisk.status[cucsStorageLocalLunPresence.{#SNMPINDEX}]
{#VDISK_LOCATION}: Layout type

MIB: CISCO-UNIFIED-COMPUTING-STORAGE-MIB

Cisco UCS storage:LocalLun:type managed object property

SNMP agent system.hw.virtualdisk.layout[cucsStorageLocalLunType.{#SNMPINDEX}]
{#VDISK_LOCATION}: Disk size

MIB: CISCO-UNIFIED-COMPUTING-STORAGE-MIB

Cisco UCS storage:LocalLun:size managed object property in MB.

SNMP agent system.hw.virtualdisk.size[cucsStorageLocalLunSize.{#SNMPINDEX}]

Preprocessing

  • Custom multiplier: 1048576

Trigger prototypes for Virtual Disk Discovery

Name Description Expression Severity Dependencies and additional info
{#VDISK_LOCATION}: Virtual disk is not in OK state

Please check virtual disk for warnings or errors

count(/Cisco UCS by SNMP/system.hw.virtualdisk.status[cucsStorageLocalLunPresence.{#SNMPINDEX}],#1,"ne","{$VDISK_OK_STATUS:\"equipped\"}")=1 Warning

LLD rule Array Controller Discovery

Name Description Type Key and additional info
Array Controller Discovery

Scanning table of Array controllers: CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageControllerTable.

SNMP agent array.discovery

Item prototypes for Array Controller Discovery

Name Description Type Key and additional info
{#DISKARRAY_LOCATION}: Disk array controller status

MIB: CISCO-UNIFIED-COMPUTING-STORAGE-MIB

SNMP agent system.hw.diskarray.status[cucsStorageControllerOperState.{#SNMPINDEX}]
{#DISKARRAY_LOCATION}: Disk array controller model

MIB: CISCO-UNIFIED-COMPUTING-STORAGE-MIB

SNMP agent system.hw.diskarray.model[cucsStorageControllerModel.{#SNMPINDEX}]

Trigger prototypes for Array Controller Discovery

Name Description Expression Severity Dependencies and additional info
{#DISKARRAY_LOCATION}: Disk array controller is in critical state

Please check the device for faults

count(/Cisco UCS by SNMP/system.hw.diskarray.status[cucsStorageControllerOperState.{#SNMPINDEX}],#1,"eq","{$DISK_ARRAY_CRIT_STATUS:\"inoperable\"}")=1 High
{#DISKARRAY_LOCATION}: Disk array controller is in warning state

Please check the device for faults

count(/Cisco UCS by SNMP/system.hw.diskarray.status[cucsStorageControllerOperState.{#SNMPINDEX}],#1,"eq","{$DISK_ARRAY_WARN_STATUS:\"degraded\"}")=1 Average Depends on:
  • {#DISKARRAY_LOCATION}: Disk array controller is in critical state
{#DISKARRAY_LOCATION}: Disk array controller is not in optimal state

Please check the device for faults

count(/Cisco UCS by SNMP/system.hw.diskarray.status[cucsStorageControllerOperState.{#SNMPINDEX}],#1,"ne","{$DISK_ARRAY_OK_STATUS:\"operable\"}")=1 Warning Depends on:
  • {#DISKARRAY_LOCATION}: Disk array controller is in critical state
  • {#DISKARRAY_LOCATION}: Disk array controller is in warning state

LLD rule Array Controller Cache Discovery

Name Description Type Key and additional info
Array Controller Cache Discovery

Scanning table of Array controllers: CISCO-UNIFIED-COMPUTING-STORAGE-MIB::cucsStorageControllerTable.

SNMP agent array.cache.discovery

Item prototypes for Array Controller Cache Discovery

Name Description Type Key and additional info
{#DISKARRAY_CACHE_LOCATION}: Disk array cache controller battery status

MIB: CISCO-UNIFIED-COMPUTING-STORAGE-MIB

SNMP agent system.hw.diskarray.cache.battery.status[cucsStorageRaidBatteryOperability.{#SNMPINDEX}]

Trigger prototypes for Array Controller Cache Discovery

Name Description Expression Severity Dependencies and additional info
{#DISKARRAY_CACHE_LOCATION}: Disk array cache controller battery is in critical state!

Please check the device for faults

count(/Cisco UCS by SNMP/system.hw.diskarray.cache.battery.status[cucsStorageRaidBatteryOperability.{#SNMPINDEX}],#1,"eq","{$DISK_ARRAY_CACHE_BATTERY_CRIT_STATUS}")=1 Average
{#DISKARRAY_CACHE_LOCATION}: Disk array cache controller battery is not in optimal state

Please check the device for faults

count(/Cisco UCS by SNMP/system.hw.diskarray.cache.battery.status[cucsStorageRaidBatteryOperability.{#SNMPINDEX}],#1,"ne","{$DISK_ARRAY_CACHE_BATTERY_OK_STATUS}")=1 Warning Depends on:
  • {#DISKARRAY_CACHE_LOCATION}: Disk array cache controller battery is in critical state!

Feedback

Please report any issues with the template at https://support.zabbix.com

You can also provide feedback, discuss the template, or ask for help at ZABBIX forums