Dell Force S-Series by SNMP
Overview
These high performance and low latency Gigabit Ethernet switches deliver the critical functionality that advanced data center network edges demand.
Requirements
Zabbix version: 7.0 and higher.
Tested versions
This template has been tested on:
- Dell Force S-Series
Configuration
Zabbix should be configured according to the instructions in the Templates out of the box section.
Setup
Refer to the vendor documentation.
Macros used
Name | Description | Default |
---|---|---|
{$CPU.UTIL.CRIT} | 90 |
|
{$TEMP_CRIT_LOW} | 5 |
|
{$TEMP_CRIT} | 65 |
|
{$TEMP_WARN} | 55 |
|
{$PSU_CRIT_STATUS} | 2 |
|
{$FAN_CRIT_STATUS} | 2 |
|
{$PSU_OK_STATUS} | 1 |
|
{$FAN_OK_STATUS} | 1 |
|
{$MEMORY.UTIL.MAX} | 90 |
|
{$SNMP.TIMEOUT} | 5m |
|
{$ICMP_LOSS_WARN} | 20 |
|
{$ICMP_RESPONSE_TIME_WARN} | 0.15 |
|
{$IF.ERRORS.WARN} | 2 |
|
{$IF.UTIL.MAX} | 90 |
|
{$IFCONTROL} | 1 |
|
{$NET.IF.IFNAME.MATCHES} | ^.*$ |
|
{$NET.IF.IFNAME.NOT_MATCHES} | Filter out loopbacks, nulls, docker veth links and docker0 bridge by default |
Macro too long. Please see the template. |
{$NET.IF.IFOPERSTATUS.MATCHES} | ^.*$ |
|
{$NET.IF.IFOPERSTATUS.NOT_MATCHES} | Ignore notPresent(6) |
^6$ |
{$NET.IF.IFADMINSTATUS.MATCHES} | Ignore notPresent(6) |
^.* |
{$NET.IF.IFADMINSTATUS.NOT_MATCHES} | Ignore down(2) administrative status |
^2$ |
{$NET.IF.IFDESCR.MATCHES} | .* |
|
{$NET.IF.IFDESCR.NOT_MATCHES} | CHANGE_IF_NEEDED |
|
{$NET.IF.IFALIAS.MATCHES} | .* |
|
{$NET.IF.IFALIAS.NOT_MATCHES} | CHANGE_IF_NEEDED |
|
{$NET.IF.IFTYPE.MATCHES} | .* |
|
{$NET.IF.IFTYPE.NOT_MATCHES} | CHANGE_IF_NEEDED |
Items
Name | Description | Type | Key and additional info |
---|---|---|---|
Dell Force S-Series: Uptime (network) | MIB: SNMPv2-MIB The time (in hundredths of a second) since the network management portion of the system was last re-initialized. |
SNMP agent | system.net.uptime[sysUpTime.0] Preprocessing
|
Dell Force S-Series: Uptime (hardware) | MIB: HOST-RESOURCES-MIB The amount of time since this host was last initialized. Note that this is different from sysUpTime in the SNMPv2-MIB [RFC1907] because sysUpTime is the uptime of the network management portion of the system. |
SNMP agent | system.hw.uptime[hrSystemUptime.0] Preprocessing
|
Dell Force S-Series: SNMP traps (fallback) | The item is used to collect all SNMP traps unmatched by other snmptrap items |
SNMP trap | snmptrap.fallback |
Dell Force S-Series: System location | MIB: SNMPv2-MIB The physical location of this node (e.g., `telephone closet, 3rd floor'). If the location is unknown, the value is the zero-length string. |
SNMP agent | system.location[sysLocation.0] Preprocessing
|
Dell Force S-Series: System contact details | MIB: SNMPv2-MIB The textual identification of the contact person for this managed node, together with information on how to contact this person. If no contact information is known, the value is the zero-length string. |
SNMP agent | system.contact[sysContact.0] Preprocessing
|
Dell Force S-Series: System object ID | MIB: SNMPv2-MIB The vendor's authoritative identification of the network management subsystem contained in the entity. This value is allocated within the SMI enterprises subtree (1.3.6.1.4.1) and provides an easy and unambiguous means for determining |
SNMP agent | system.objectid[sysObjectID.0] Preprocessing
|
Dell Force S-Series: System name | MIB: SNMPv2-MIB An administratively-assigned name for this managed node.By convention, this is the node's fully-qualified domain name. If the name is unknown, the value is the zero-length string. |
SNMP agent | system.name Preprocessing
|
Dell Force S-Series: System description | MIB: SNMPv2-MIB A textual description of the entity. This value should include the full name and version identification of the system's hardware type, software operating-system, and networking software. |
SNMP agent | system.descr[sysDescr.0] Preprocessing
|
Dell Force S-Series: SNMP agent availability | Availability of SNMP checks on the host. The value of this item corresponds to availability icons in the host list. Possible value: 0 - not available 1 - available 2 - unknown |
Zabbix internal | zabbix[host,snmp,available] |
Dell Force S-Series: ICMP ping | Simple check | icmpping | |
Dell Force S-Series: ICMP loss | Simple check | icmppingloss | |
Dell Force S-Series: ICMP response time | Simple check | icmppingsec |
Triggers
Name | Description | Expression | Severity | Dependencies and additional info |
---|---|---|---|---|
Dell Force S-Series: Host has been restarted | Uptime is less than 10 minutes. |
(last(/Dell Force S-Series by SNMP/system.hw.uptime[hrSystemUptime.0])>0 and last(/Dell Force S-Series by SNMP/system.hw.uptime[hrSystemUptime.0])<10m) or (last(/Dell Force S-Series by SNMP/system.hw.uptime[hrSystemUptime.0])=0 and last(/Dell Force S-Series by SNMP/system.net.uptime[sysUpTime.0])<10m) |
Warning | Manual close: Yes Depends on:
|
Dell Force S-Series: System name has changed | The name of the system has changed. Acknowledge to close the problem manually. |
last(/Dell Force S-Series by SNMP/system.name,#1)<>last(/Dell Force S-Series by SNMP/system.name,#2) and length(last(/Dell Force S-Series by SNMP/system.name))>0 |
Info | Manual close: Yes |
Dell Force S-Series: No SNMP data collection | SNMP is not available for polling. Please check device connectivity and SNMP settings. |
max(/Dell Force S-Series by SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0 |
Warning | Depends on:
|
Dell Force S-Series: Unavailable by ICMP ping | Last three attempts returned timeout. Please check device connectivity. |
max(/Dell Force S-Series by SNMP/icmpping,#3)=0 |
High | |
Dell Force S-Series: High ICMP ping loss | min(/Dell Force S-Series by SNMP/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/Dell Force S-Series by SNMP/icmppingloss,5m)<100 |
Warning | Depends on:
|
|
Dell Force S-Series: High ICMP ping response time | avg(/Dell Force S-Series by SNMP/icmppingsec,5m)>{$ICMP_RESPONSE_TIME_WARN} |
Warning | Depends on:
|
LLD rule CPU and Memory and Flash Discovery
Name | Description | Type | Key and additional info |
---|---|---|---|
CPU and Memory and Flash Discovery | SNMP agent | module.discovery |
Item prototypes for CPU and Memory and Flash Discovery
Name | Description | Type | Key and additional info |
---|---|---|---|
#{#SNMPINDEX}: CPU utilization | MIB: F10-S-SERIES-CHASSIS-MIB CPU utilization in percentage for last 1 minute. |
SNMP agent | system.cpu.util[chStackUnitCpuUtil1Min.{#SNMPINDEX}] |
#{#SNMPINDEX}: Memory utilization | MIB: F10-S-SERIES-CHASSIS-MIB Total memory usage in percentage. |
SNMP agent | vm.memory.util[chStackUnitMemUsageUtil.{#SNMPINDEX}] |
Trigger prototypes for CPU and Memory and Flash Discovery
Name | Description | Expression | Severity | Dependencies and additional info |
---|---|---|---|---|
#{#SNMPINDEX}: High CPU utilization | The CPU utilization is too high. The system might be slow to respond. |
min(/Dell Force S-Series by SNMP/system.cpu.util[chStackUnitCpuUtil1Min.{#SNMPINDEX}],5m)>{$CPU.UTIL.CRIT} |
Warning | |
#{#SNMPINDEX}: High memory utilization | The system is running out of free memory. |
min(/Dell Force S-Series by SNMP/vm.memory.util[chStackUnitMemUsageUtil.{#SNMPINDEX}],5m)>{$MEMORY.UTIL.MAX} |
Average |
LLD rule PSU Discovery
Name | Description | Type | Key and additional info |
---|---|---|---|
PSU Discovery | A list of power supply residents in the S-series chassis. |
SNMP agent | psu.discovery |
Item prototypes for PSU Discovery
Name | Description | Type | Key and additional info |
---|---|---|---|
PSU {#SNMPVALUE}: Power supply status | MIB: F10-S-SERIES-CHASSIS-MIB The status of the power supply {#SNMPVALUE} |
SNMP agent | sensor.psu.status[chSysPowerSupplyOperStatus.{#SNMPINDEX}] |
Trigger prototypes for PSU Discovery
Name | Description | Expression | Severity | Dependencies and additional info |
---|---|---|---|---|
PSU {#SNMPVALUE}: Power supply is in critical state | Please check the power supply unit for errors |
count(/Dell Force S-Series by SNMP/sensor.psu.status[chSysPowerSupplyOperStatus.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS}")=1 |
Average | |
PSU {#SNMPVALUE}: Power supply is not in normal state | Please check the power supply unit for errors |
count(/Dell Force S-Series by SNMP/sensor.psu.status[chSysPowerSupplyOperStatus.{#SNMPINDEX}],#1,"ne","{$PSU_OK_STATUS}")=1 |
Info | Depends on:
|
LLD rule FAN Discovery
Name | Description | Type | Key and additional info |
---|---|---|---|
FAN Discovery | SNMP agent | fan.discovery |
Item prototypes for FAN Discovery
Name | Description | Type | Key and additional info |
---|---|---|---|
Fan {#SNMPVALUE}: Fan status | MIB: F10-S-SERIES-CHASSIS-MIB The status of the fan tray {#SNMPVALUE}. |
SNMP agent | sensor.fan.status[chSysFanTrayOperStatus.{#SNMPINDEX}] |
Trigger prototypes for FAN Discovery
Name | Description | Expression | Severity | Dependencies and additional info |
---|---|---|---|---|
Fan {#SNMPVALUE}: Fan is in critical state | Please check the fan unit |
count(/Dell Force S-Series by SNMP/sensor.fan.status[chSysFanTrayOperStatus.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS}")=1 |
Average | |
Fan {#SNMPVALUE}: Fan is not in normal state | Please check the fan unit |
count(/Dell Force S-Series by SNMP/sensor.fan.status[chSysFanTrayOperStatus.{#SNMPINDEX}],#1,"ne","{$FAN_OK_STATUS}")=1 |
Info | Depends on:
|
LLD rule Stack Unit Discovery
Name | Description | Type | Key and additional info |
---|---|---|---|
Stack Unit Discovery | SNMP agent | stack.discovery |
Item prototypes for Stack Unit Discovery
Name | Description | Type | Key and additional info |
---|---|---|---|
Device {#SNMPVALUE}: Temperature | MIB: F10-S-SERIES-CHASSIS-MIB The temperature of the unit. |
SNMP agent | sensor.temp.value[chStackUnitTemp.{#SNMPINDEX}] |
#{#SNMPVALUE}: Hardware model name | MIB: F10-S-SERIES-CHASSIS-MIB The plugged-in model ID for this unit. |
SNMP agent | system.hw.model[chStackUnitModelID.{#SNMPINDEX}] Preprocessing
|
#{#SNMPVALUE}: Hardware serial number | MIB: F10-S-SERIES-CHASSIS-MIB The unit's serial number. |
SNMP agent | system.hw.serialnumber[chStackUnitSerialNumber.{#SNMPINDEX}] Preprocessing
|
#{#SNMPVALUE}: Hardware version(revision) | MIB: F10-S-SERIES-CHASSIS-MIB The unit manufacturer's product revision |
SNMP agent | system.hw.version[chStackUnitProductRev.{#SNMPINDEX}] Preprocessing
|
#{#SNMPVALUE}: Operating system | MIB: F10-S-SERIES-CHASSIS-MIB Current code version of this unit. |
SNMP agent | system.sw.os[chStackUnitCodeVersion.{#SNMPINDEX}] Preprocessing
|
Trigger prototypes for Stack Unit Discovery
Name | Description | Expression | Severity | Dependencies and additional info |
---|---|---|---|---|
Device {#SNMPVALUE}: Temperature is above warning threshold | This trigger uses temperature sensor values as well as temperature sensor status if available |
avg(/Dell Force S-Series by SNMP/sensor.temp.value[chStackUnitTemp.{#SNMPINDEX}],5m)>{$TEMP_WARN:"{#SNMPVALUE}"} |
Warning | Depends on:
|
Device {#SNMPVALUE}: Temperature is above critical threshold | This trigger uses temperature sensor values as well as temperature sensor status if available |
avg(/Dell Force S-Series by SNMP/sensor.temp.value[chStackUnitTemp.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"{#SNMPVALUE}"} |
High | |
Device {#SNMPVALUE}: Temperature is too low | avg(/Dell Force S-Series by SNMP/sensor.temp.value[chStackUnitTemp.{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:"{#SNMPVALUE}"} |
Average | ||
#{#SNMPVALUE}: Device has been replaced | Device serial number has changed. Acknowledge to close the problem manually. |
last(/Dell Force S-Series by SNMP/system.hw.serialnumber[chStackUnitSerialNumber.{#SNMPINDEX}],#1)<>last(/Dell Force S-Series by SNMP/system.hw.serialnumber[chStackUnitSerialNumber.{#SNMPINDEX}],#2) and length(last(/Dell Force S-Series by SNMP/system.hw.serialnumber[chStackUnitSerialNumber.{#SNMPINDEX}]))>0 |
Info | Manual close: Yes |
#{#SNMPVALUE}: Operating system description has changed | The description of the operating system has changed. Possible reasons are that the system has been updated or replaced. Acknowledge to close the problem manually. |
last(/Dell Force S-Series by SNMP/system.sw.os[chStackUnitCodeVersion.{#SNMPINDEX}],#1)<>last(/Dell Force S-Series by SNMP/system.sw.os[chStackUnitCodeVersion.{#SNMPINDEX}],#2) and length(last(/Dell Force S-Series by SNMP/system.sw.os[chStackUnitCodeVersion.{#SNMPINDEX}]))>0 |
Info | Manual close: Yes Depends on:
|
LLD rule Network interfaces discovery
Name | Description | Type | Key and additional info |
---|---|---|---|
Network interfaces discovery | Discovering interfaces from IF-MIB. |
SNMP agent | net.if.discovery |
Item prototypes for Network interfaces discovery
Name | Description | Type | Key and additional info |
---|---|---|---|
Interface {#IFNAME}({#IFALIAS}): Operational status | MIB: IF-MIB The current operational state of the interface. - The testing(3) state indicates that no operational packet scan be passed - If ifAdminStatus is down(2) then ifOperStatus should be down(2) - If ifAdminStatus is changed to up(1) then ifOperStatus should change to up(1) if the interface is ready to transmit and receive network traffic - It should change todormant(5) if the interface is waiting for external actions (such as a serial line waiting for an incoming connection) - It should remain in the down(2) state if and only if there is a fault that prevents it from going to the up(1) state - It should remain in the notPresent(6) state if the interface has missing(typically, hardware) components. |
SNMP agent | net.if.status[ifOperStatus.{#SNMPINDEX}] |
Interface {#IFNAME}({#IFALIAS}): Bits received | MIB: IF-MIB The total number of octets received on the interface, including framing characters. This object is a 64-bit version of ifInOctets. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP agent | net.if.in[ifHCInOctets.{#SNMPINDEX}] Preprocessing
|
Interface {#IFNAME}({#IFALIAS}): Bits sent | MIB: IF-MIB The total number of octets transmitted out of the interface, including framing characters. This object is a 64-bit version of ifOutOctets.Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP agent | net.if.out[ifHCOutOctets.{#SNMPINDEX}] Preprocessing
|
Interface {#IFNAME}({#IFALIAS}): Inbound packets with errors | MIB: IF-MIB For packet-oriented interfaces, the number of inbound packets that contained errors preventing them from being deliverable to a higher-layer protocol. For character-oriented or fixed-length interfaces, the number of inbound transmission units that contained errors preventing them from being deliverable to a higher-layer protocol. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP agent | net.if.in.errors[ifInErrors.{#SNMPINDEX}] Preprocessing
|
Interface {#IFNAME}({#IFALIAS}): Outbound packets with errors | MIB: IF-MIB For packet-oriented interfaces, the number of outbound packets that contained errors preventing them from being deliverable to a higher-layer protocol. For character-oriented or fixed-length interfaces, the number of outbound transmission units that contained errors preventing them from being deliverable to a higher-layer protocol. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP agent | net.if.out.errors[ifOutErrors.{#SNMPINDEX}] Preprocessing
|
Interface {#IFNAME}({#IFALIAS}): Outbound packets discarded | MIB: IF-MIB The number of outbound packets which were chosen to be discarded even though no errors had been detected to prevent their being deliverable to a higher-layer protocol. One possible reason for discarding such a packet could be to free up buffer space. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP agent | net.if.out.discards[ifOutDiscards.{#SNMPINDEX}] Preprocessing
|
Interface {#IFNAME}({#IFALIAS}): Inbound packets discarded | MIB: IF-MIB The number of inbound packets which were chosen to be discarded even though no errors had been detected to prevent their being deliverable to a higher-layer protocol. One possible reason for discarding such a packet could be to free up buffer space. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime. |
SNMP agent | net.if.in.discards[ifInDiscards.{#SNMPINDEX}] Preprocessing
|
Interface {#IFNAME}({#IFALIAS}): Interface type | MIB: IF-MIB The type of interface. Additional values for ifType are assigned by the Internet Assigned Numbers Authority (IANA), through updating the syntax of the IANAifType textual convention. |
SNMP agent | net.if.type[ifType.{#SNMPINDEX}] Preprocessing
|
Interface {#IFNAME}({#IFALIAS}): Speed | MIB: IF-MIB An estimate of the interface's current bandwidth in units of 1,000,000 bits per second. If this object reports a value of |
SNMP agent | net.if.speed[ifHighSpeed.{#SNMPINDEX}] Preprocessing
|
Trigger prototypes for Network interfaces discovery
Name | Description | Expression | Severity | Dependencies and additional info |
---|---|---|---|---|
Interface {#IFNAME}({#IFALIAS}): Link down | This trigger expression works as follows: |
{$IFCONTROL:"{#IFNAME}"}=1 and last(/Dell Force S-Series by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/Dell Force S-Series by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/Dell Force S-Series by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#2)) |
Average | Manual close: Yes |
Interface {#IFNAME}({#IFALIAS}): High bandwidth usage | The utilization of the network interface is close to its estimated maximum bandwidth. |
(avg(/Dell Force S-Series by SNMP/net.if.in[ifHCInOctets.{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Dell Force S-Series by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}]) or avg(/Dell Force S-Series by SNMP/net.if.out[ifHCOutOctets.{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Dell Force S-Series by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])) and last(/Dell Force S-Series by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0 |
Warning | Manual close: Yes Depends on:
|
Interface {#IFNAME}({#IFALIAS}): High error rate | It recovers when it is below 80% of the |
min(/Dell Force S-Series by SNMP/net.if.in.errors[ifInErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"} or min(/Dell Force S-Series by SNMP/net.if.out.errors[ifOutErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"} |
Warning | Manual close: Yes Depends on:
|
Interface {#IFNAME}({#IFALIAS}): Ethernet has changed to lower speed than it was before | This Ethernet connection has transitioned down from its known maximum speed. This might be a sign of autonegotiation issues. Acknowledge to close the problem manually. |
change(/Dell Force S-Series by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])<0 and last(/Dell Force S-Series by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0 and ( last(/Dell Force S-Series by SNMP/net.if.type[ifType.{#SNMPINDEX}])=6 or last(/Dell Force S-Series by SNMP/net.if.type[ifType.{#SNMPINDEX}])=7 or last(/Dell Force S-Series by SNMP/net.if.type[ifType.{#SNMPINDEX}])=11 or last(/Dell Force S-Series by SNMP/net.if.type[ifType.{#SNMPINDEX}])=62 or last(/Dell Force S-Series by SNMP/net.if.type[ifType.{#SNMPINDEX}])=69 or last(/Dell Force S-Series by SNMP/net.if.type[ifType.{#SNMPINDEX}])=117 ) and (last(/Dell Force S-Series by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2) |
Info | Manual close: Yes Depends on:
|
LLD rule EtherLike-MIB Discovery
Name | Description | Type | Key and additional info |
---|---|---|---|
EtherLike-MIB Discovery | Discovering interfaces from IF-MIB and EtherLike-MIB. Interfaces with up(1) Operational Status are discovered. |
SNMP agent | net.if.duplex.discovery Preprocessing
|
Item prototypes for EtherLike-MIB Discovery
Name | Description | Type | Key and additional info |
---|---|---|---|
Interface {#IFNAME}({#IFALIAS}): Duplex status | MIB: EtherLike-MIB The current mode of operation of the MAC entity. 'unknown' indicates that the current duplex mode could not be determined. Management control of the duplex mode is accomplished through the MAU MIB. When an interface does not support autonegotiation, or when autonegotiation is not enabled, the duplex mode is controlled using ifMauDefaultType. When autonegotiation is supported and enabled, duplex mode is controlled using ifMauAutoNegAdvertisedBits. In either case, the currently operating duplex mode is reflected both in this object and in ifMauType. Note that this object provides redundant information with ifMauType. Normally, redundant objects are discouraged. However, in this instance, it allows a management application to determine the duplex status of an interface without having to know every possible value of ifMauType. This was felt to be sufficiently valuable to justify the redundancy. Reference: [IEEE 802.3 Std.], 30.3.1.1.32,aDuplexStatus. |
SNMP agent | net.if.duplex[dot3StatsDuplexStatus.{#SNMPINDEX}] |
Trigger prototypes for EtherLike-MIB Discovery
Name | Description | Expression | Severity | Dependencies and additional info |
---|---|---|---|---|
Interface {#IFNAME}({#IFALIAS}): In half-duplex mode | Please check autonegotiation settings and cabling |
last(/Dell Force S-Series by SNMP/net.if.duplex[dot3StatsDuplexStatus.{#SNMPINDEX}])=2 |
Warning | Manual close: Yes |
Feedback
Please report any issues with the template at https://support.zabbix.com
You can also provide feedback, discuss the template, or ask for help at ZABBIX forums