You can not select more than 25 topics Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.

209 lines
26 KiB

This file contains invisible Unicode characters!

This file contains invisible Unicode characters that may be processed differently from what appears below. If your use case is intentional and legitimate, you can safely ignore this warning. Use the Escape button to reveal hidden characters.

# Extreme EXOS by SNMP
## Overview
ExtremeXOS is the software or the network operating system used in newer Extreme Networks network switches. It is Extreme Networks second generation operating system after the VxWorks based ExtremeWare operating system. ExtremeXOS is based on the Linux kernel and BusyBox.
## Requirements
Zabbix version: 7.0 and higher.
## Tested versions
This template has been tested on:
- Extreme EXOS
## Configuration
> Zabbix should be configured according to the instructions in the [Templates out of the box](https://www.zabbix.com/documentation/7.0/manual/config/templates_out_of_the_box) section.
## Setup
Refer to the vendor documentation.
### Macros used
|Name|Description|Default|
|----|-----------|-------|
|{$CPU.UTIL.CRIT}||`90`|
|{$TEMP_CRIT_LOW}||`5`|
|{$TEMP_CRIT}||`65`|
|{$TEMP_WARN}||`55`|
|{$TEMP_CRIT_STATUS}||`1`|
|{$PSU_CRIT_STATUS}||`3`|
|{$FAN_CRIT_STATUS}||`2`|
|{$MEMORY.UTIL.MAX}||`90`|
|{$SNMP.TIMEOUT}||`5m`|
|{$ICMP_LOSS_WARN}||`20`|
|{$ICMP_RESPONSE_TIME_WARN}||`0.15`|
|{$IF.ERRORS.WARN}||`2`|
|{$IF.UTIL.MAX}||`90`|
|{$IFCONTROL}||`1`|
|{$NET.IF.IFNAME.MATCHES}||`^.*$`|
|{$NET.IF.IFNAME.NOT_MATCHES}|<p>Filter out loopbacks, nulls, docker veth links and docker0 bridge by default</p>|`Macro too long. Please see the template.`|
|{$NET.IF.IFOPERSTATUS.MATCHES}||`^.*$`|
|{$NET.IF.IFOPERSTATUS.NOT_MATCHES}|<p>Ignore notPresent(6)</p>|`^6$`|
|{$NET.IF.IFADMINSTATUS.MATCHES}|<p>Ignore notPresent(6)</p>|`^.*`|
|{$NET.IF.IFADMINSTATUS.NOT_MATCHES}|<p>Ignore down(2) administrative status</p>|`^2$`|
|{$NET.IF.IFDESCR.MATCHES}||`.*`|
|{$NET.IF.IFDESCR.NOT_MATCHES}||`CHANGE_IF_NEEDED`|
|{$NET.IF.IFALIAS.MATCHES}||`.*`|
|{$NET.IF.IFALIAS.NOT_MATCHES}||`CHANGE_IF_NEEDED`|
|{$NET.IF.IFTYPE.MATCHES}||`.*`|
|{$NET.IF.IFTYPE.NOT_MATCHES}||`CHANGE_IF_NEEDED`|
### Items
|Name|Description|Type|Key and additional info|
|----|-----------|----|-----------------------|
|Extreme EXOS: CPU utilization|<p>MIB: EXTREME-SOFTWARE-MONITOR-MIB</p><p>Total CPU utilization (percentage) as of last sampling.</p>|SNMP agent|system.cpu.util[extremeCpuMonitorTotalUtilization.0]|
|Device: Temperature|<p>MIB: EXTREME-SYSTEM-MIB</p><p>Temperature readings of testpoint: Device</p><p>Reference: https://gtacknowledge.extremenetworks.com/articles/Q_A/Does-EXOS-support-temperature-polling-via-SNMP-on-all-nodes-in-a-stack</p>|SNMP agent|sensor.temp.value[extremeCurrentTemperature.0]|
|Device: Temperature status|<p>MIB: EXTREME-SYSTEM-MIB</p><p>Temperature status of testpoint: Device</p>|SNMP agent|sensor.temp.status[extremeOverTemperatureAlarm.0]|
|Extreme EXOS: Hardware model name|<p>MIB: ENTITY-MIB</p>|SNMP agent|system.hw.model<p>**Preprocessing**</p><ul><li><p>Discard unchanged with heartbeat: `1d`</p></li></ul>|
|Extreme EXOS: Hardware serial number|<p>MIB: ENTITY-MIB</p>|SNMP agent|system.hw.serialnumber<p>**Preprocessing**</p><ul><li><p>Discard unchanged with heartbeat: `1d`</p></li></ul>|
|Extreme EXOS: Firmware version|<p>MIB: ENTITY-MIB</p>|SNMP agent|system.hw.firmware<p>**Preprocessing**</p><ul><li><p>Discard unchanged with heartbeat: `1d`</p></li></ul>|
|Extreme EXOS: Hardware version(revision)|<p>MIB: ENTITY-MIB</p>|SNMP agent|system.hw.version<p>**Preprocessing**</p><ul><li><p>Discard unchanged with heartbeat: `1d`</p></li></ul>|
|Extreme EXOS: Operating system|<p>MIB: EXTREME-SYSTEM-MIB</p><p>The software revision of the primary image stored in this device.</p><p>This string will have a zero length if the revision is unknown, invalid or not present.</p><p>This will also be reported in RMON2 probeSoftwareRev if this is the software image currently running in the device.</p>|SNMP agent|system.sw.os[extremePrimarySoftwareRev.0]<p>**Preprocessing**</p><ul><li><p>Discard unchanged with heartbeat: `1d`</p></li></ul>|
|Extreme EXOS: Uptime (network)|<p>MIB: SNMPv2-MIB</p><p>The time (in hundredths of a second) since the network management portion of the system was last re-initialized.</p>|SNMP agent|system.net.uptime[sysUpTime.0]<p>**Preprocessing**</p><ul><li><p>Custom multiplier: `0.01`</p></li></ul>|
|Extreme EXOS: Uptime (hardware)|<p>MIB: HOST-RESOURCES-MIB</p><p>The amount of time since this host was last initialized. Note that this is different from sysUpTime in the SNMPv2-MIB [RFC1907] because sysUpTime is the uptime of the network management portion of the system.</p>|SNMP agent|system.hw.uptime[hrSystemUptime.0]<p>**Preprocessing**</p><ul><li><p>Check for not supported value</p><p>Custom on fail: Set value to: `0`</p></li><li><p>Custom multiplier: `0.01`</p></li></ul>|
|Extreme EXOS: SNMP traps (fallback)|<p>The item is used to collect all SNMP traps unmatched by other snmptrap items</p>|SNMP trap|snmptrap.fallback|
|Extreme EXOS: System location|<p>MIB: SNMPv2-MIB</p><p>The physical location of this node (e.g., `telephone closet, 3rd floor'). If the location is unknown, the value is the zero-length string.</p>|SNMP agent|system.location[sysLocation.0]<p>**Preprocessing**</p><ul><li><p>Discard unchanged with heartbeat: `12h`</p></li></ul>|
|Extreme EXOS: System contact details|<p>MIB: SNMPv2-MIB</p><p>The textual identification of the contact person for this managed node, together with information on how to contact this person. If no contact information is known, the value is the zero-length string.</p>|SNMP agent|system.contact[sysContact.0]<p>**Preprocessing**</p><ul><li><p>Discard unchanged with heartbeat: `12h`</p></li></ul>|
|Extreme EXOS: System object ID|<p>MIB: SNMPv2-MIB</p><p>The vendor's authoritative identification of the network management subsystem contained in the entity. This value is allocated within the SMI enterprises subtree (1.3.6.1.4.1) and provides an easy and unambiguous means for determining`what kind of box' is being managed. For example, if vendor`Flintstones, Inc.' was assigned the subtree1.3.6.1.4.1.4242, it could assign the identifier 1.3.6.1.4.1.4242.1.1 to its `Fred Router'.</p>|SNMP agent|system.objectid[sysObjectID.0]<p>**Preprocessing**</p><ul><li><p>Discard unchanged with heartbeat: `12h`</p></li></ul>|
|Extreme EXOS: System name|<p>MIB: SNMPv2-MIB</p><p>An administratively-assigned name for this managed node.By convention, this is the node's fully-qualified domain name. If the name is unknown, the value is the zero-length string.</p>|SNMP agent|system.name<p>**Preprocessing**</p><ul><li><p>Discard unchanged with heartbeat: `12h`</p></li></ul>|
|Extreme EXOS: System description|<p>MIB: SNMPv2-MIB</p><p>A textual description of the entity. This value should</p><p>include the full name and version identification of the system's hardware type, software operating-system, and</p><p>networking software.</p>|SNMP agent|system.descr[sysDescr.0]<p>**Preprocessing**</p><ul><li><p>Discard unchanged with heartbeat: `12h`</p></li></ul>|
|Extreme EXOS: SNMP agent availability|<p>Availability of SNMP checks on the host. The value of this item corresponds to availability icons in the host list.</p><p>Possible value:</p><p>0 - not available</p><p>1 - available</p><p>2 - unknown</p>|Zabbix internal|zabbix[host,snmp,available]|
|Extreme EXOS: ICMP ping||Simple check|icmpping|
|Extreme EXOS: ICMP loss||Simple check|icmppingloss|
|Extreme EXOS: ICMP response time||Simple check|icmppingsec|
### Triggers
|Name|Description|Expression|Severity|Dependencies and additional info|
|----|-----------|----------|--------|--------------------------------|
|Extreme EXOS: High CPU utilization|<p>The CPU utilization is too high. The system might be slow to respond.</p>|`min(/Extreme EXOS by SNMP/system.cpu.util[extremeCpuMonitorTotalUtilization.0],5m)>{$CPU.UTIL.CRIT}`|Warning||
|Device: Temperature is above warning threshold|<p>This trigger uses temperature sensor values as well as temperature sensor status if available</p>|`avg(/Extreme EXOS by SNMP/sensor.temp.value[extremeCurrentTemperature.0],5m)>{$TEMP_WARN}`|Warning|**Depends on**:<br><ul><li>Device: Temperature is above critical threshold</li></ul>|
|Device: Temperature is above critical threshold|<p>This trigger uses temperature sensor values as well as temperature sensor status if available</p>|`avg(/Extreme EXOS by SNMP/sensor.temp.value[extremeCurrentTemperature.0],5m)>{$TEMP_CRIT} or last(/Extreme EXOS by SNMP/sensor.temp.status[extremeOverTemperatureAlarm.0])={$TEMP_CRIT_STATUS}`|High||
|Device: Temperature is too low||`avg(/Extreme EXOS by SNMP/sensor.temp.value[extremeCurrentTemperature.0],5m)<{$TEMP_CRIT_LOW}`|Average||
|Extreme EXOS: Device has been replaced|<p>Device serial number has changed. Acknowledge to close the problem manually.</p>|`last(/Extreme EXOS by SNMP/system.hw.serialnumber,#1)<>last(/Extreme EXOS by SNMP/system.hw.serialnumber,#2) and length(last(/Extreme EXOS by SNMP/system.hw.serialnumber))>0`|Info|**Manual close**: Yes|
|Extreme EXOS: Firmware has changed|<p>Firmware version has changed. Acknowledge to close the problem manually.</p>|`last(/Extreme EXOS by SNMP/system.hw.firmware,#1)<>last(/Extreme EXOS by SNMP/system.hw.firmware,#2) and length(last(/Extreme EXOS by SNMP/system.hw.firmware))>0`|Info|**Manual close**: Yes|
|Extreme EXOS: Operating system description has changed|<p>Operating system description has changed. Possible reasons that system has been updated or replaced. Acknowledge to close the problem manually.</p>|`last(/Extreme EXOS by SNMP/system.sw.os[extremePrimarySoftwareRev.0],#1)<>last(/Extreme EXOS by SNMP/system.sw.os[extremePrimarySoftwareRev.0],#2) and length(last(/Extreme EXOS by SNMP/system.sw.os[extremePrimarySoftwareRev.0]))>0`|Info|**Manual close**: Yes<br>**Depends on**:<br><ul><li>Extreme EXOS: System name has changed</li></ul>|
|Extreme EXOS: Host has been restarted|<p>Uptime is less than 10 minutes.</p>|`(last(/Extreme EXOS by SNMP/system.hw.uptime[hrSystemUptime.0])>0 and last(/Extreme EXOS by SNMP/system.hw.uptime[hrSystemUptime.0])<10m) or (last(/Extreme EXOS by SNMP/system.hw.uptime[hrSystemUptime.0])=0 and last(/Extreme EXOS by SNMP/system.net.uptime[sysUpTime.0])<10m)`|Warning|**Manual close**: Yes<br>**Depends on**:<br><ul><li>Extreme EXOS: No SNMP data collection</li></ul>|
|Extreme EXOS: System name has changed|<p>The name of the system has changed. Acknowledge to close the problem manually.</p>|`last(/Extreme EXOS by SNMP/system.name,#1)<>last(/Extreme EXOS by SNMP/system.name,#2) and length(last(/Extreme EXOS by SNMP/system.name))>0`|Info|**Manual close**: Yes|
|Extreme EXOS: No SNMP data collection|<p>SNMP is not available for polling. Please check device connectivity and SNMP settings.</p>|`max(/Extreme EXOS by SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0`|Warning|**Depends on**:<br><ul><li>Extreme EXOS: Unavailable by ICMP ping</li></ul>|
|Extreme EXOS: Unavailable by ICMP ping|<p>Last three attempts returned timeout. Please check device connectivity.</p>|`max(/Extreme EXOS by SNMP/icmpping,#3)=0`|High||
|Extreme EXOS: High ICMP ping loss||`min(/Extreme EXOS by SNMP/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/Extreme EXOS by SNMP/icmppingloss,5m)<100`|Warning|**Depends on**:<br><ul><li>Extreme EXOS: Unavailable by ICMP ping</li></ul>|
|Extreme EXOS: High ICMP ping response time||`avg(/Extreme EXOS by SNMP/icmppingsec,5m)>{$ICMP_RESPONSE_TIME_WARN}`|Warning|**Depends on**:<br><ul><li>Extreme EXOS: High ICMP ping loss</li><li>Extreme EXOS: Unavailable by ICMP ping</li></ul>|
### LLD rule Memory Discovery
|Name|Description|Type|Key and additional info|
|----|-----------|----|-----------------------|
|Memory Discovery||SNMP agent|memory.discovery|
### Item prototypes for Memory Discovery
|Name|Description|Type|Key and additional info|
|----|-----------|----|-----------------------|
|#{#SNMPVALUE}: Available memory|<p>MIB: EXTREME-SOFTWARE-MONITOR-MIB</p><p>Total amount of free memory in Kbytes in the system.</p>|SNMP agent|vm.memory.available[extremeMemoryMonitorSystemFree.{#SNMPINDEX}]<p>**Preprocessing**</p><ul><li><p>Custom multiplier: `1024`</p></li></ul>|
|#{#SNMPVALUE}: Total memory|<p>MIB: EXTREME-SOFTWARE-MONITOR-MIB</p><p>Total amount of DRAM in Kbytes in the system.</p>|SNMP agent|vm.memory.total[extremeMemoryMonitorSystemTotal.{#SNMPINDEX}]<p>**Preprocessing**</p><ul><li><p>Custom multiplier: `1024`</p></li></ul>|
|#{#SNMPVALUE}: Memory utilization|<p>Memory utilization in %.</p>|Calculated|vm.memory.util[{#SNMPVALUE}]|
### Trigger prototypes for Memory Discovery
|Name|Description|Expression|Severity|Dependencies and additional info|
|----|-----------|----------|--------|--------------------------------|
|#{#SNMPVALUE}: High memory utilization|<p>The system is running out of free memory.</p>|`min(/Extreme EXOS by SNMP/vm.memory.util[{#SNMPVALUE}],5m)>{$MEMORY.UTIL.MAX}`|Average||
### LLD rule PSU Discovery
|Name|Description|Type|Key and additional info|
|----|-----------|----|-----------------------|
|PSU Discovery|<p>Table of status of all power supplies in the system.</p>|SNMP agent|psu.discovery|
### Item prototypes for PSU Discovery
|Name|Description|Type|Key and additional info|
|----|-----------|----|-----------------------|
|PSU {#SNMPVALUE}: Power supply status|<p>MIB: EXTREME-SYSTEM-MIB</p><p>Status of the power supply {#SNMPVALUE}</p>|SNMP agent|sensor.psu.status[extremePowerSupplyStatus.{#SNMPINDEX}]|
### Trigger prototypes for PSU Discovery
|Name|Description|Expression|Severity|Dependencies and additional info|
|----|-----------|----------|--------|--------------------------------|
|PSU {#SNMPVALUE}: Power supply is in critical state|<p>Please check the power supply unit for errors</p>|`count(/Extreme EXOS by SNMP/sensor.psu.status[extremePowerSupplyStatus.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS}")=1`|Average||
### LLD rule FAN Discovery
|Name|Description|Type|Key and additional info|
|----|-----------|----|-----------------------|
|FAN Discovery||SNMP agent|fan.discovery|
### Item prototypes for FAN Discovery
|Name|Description|Type|Key and additional info|
|----|-----------|----|-----------------------|
|Fan {#SNMPVALUE}: Fan status|<p>MIB: EXTREME-SYSTEM-MIB</p><p>Operational status of a cooling fan.</p>|SNMP agent|sensor.fan.status[extremeFanOperational.{#SNMPINDEX}]|
|Fan {#SNMPVALUE}: Fan speed|<p>MIB: EXTREME-SYSTEM-MIB</p><p>The speed (RPM) of a cooling fan in the fantray {#SNMPVALUE}</p>|SNMP agent|sensor.fan.speed[extremeFanSpeed.{#SNMPINDEX}]|
### Trigger prototypes for FAN Discovery
|Name|Description|Expression|Severity|Dependencies and additional info|
|----|-----------|----------|--------|--------------------------------|
|Fan {#SNMPVALUE}: Fan is in critical state|<p>Please check the fan unit</p>|`count(/Extreme EXOS by SNMP/sensor.fan.status[extremeFanOperational.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS}")=1`|Average||
### LLD rule Network interfaces discovery
|Name|Description|Type|Key and additional info|
|----|-----------|----|-----------------------|
|Network interfaces discovery|<p>Discovering interfaces from IF-MIB.</p>|SNMP agent|net.if.discovery|
### Item prototypes for Network interfaces discovery
|Name|Description|Type|Key and additional info|
|----|-----------|----|-----------------------|
|Interface {#IFNAME}({#IFALIAS}): Operational status|<p>MIB: IF-MIB</p><p>The current operational state of the interface.</p><p>- The testing(3) state indicates that no operational packet scan be passed</p><p>- If ifAdminStatus is down(2) then ifOperStatus should be down(2)</p><p>- If ifAdminStatus is changed to up(1) then ifOperStatus should change to up(1) if the interface is ready to transmit and receive network traffic</p><p>- It should change todormant(5) if the interface is waiting for external actions (such as a serial line waiting for an incoming connection)</p><p>- It should remain in the down(2) state if and only if there is a fault that prevents it from going to the up(1) state</p><p>- It should remain in the notPresent(6) state if the interface has missing(typically, hardware) components.</p>|SNMP agent|net.if.status[ifOperStatus.{#SNMPINDEX}]|
|Interface {#IFNAME}({#IFALIAS}): Bits received|<p>MIB: IF-MIB</p><p>The total number of octets received on the interface, including framing characters. This object is a 64-bit version of ifInOctets. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime.</p>|SNMP agent|net.if.in[ifHCInOctets.{#SNMPINDEX}]<p>**Preprocessing**</p><ul><li>Change per second</li><li><p>Custom multiplier: `8`</p></li></ul>|
|Interface {#IFNAME}({#IFALIAS}): Bits sent|<p>MIB: IF-MIB</p><p>The total number of octets transmitted out of the interface, including framing characters. This object is a 64-bit version of ifOutOctets.Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime.</p>|SNMP agent|net.if.out[ifHCOutOctets.{#SNMPINDEX}]<p>**Preprocessing**</p><ul><li>Change per second</li><li><p>Custom multiplier: `8`</p></li></ul>|
|Interface {#IFNAME}({#IFALIAS}): Inbound packets with errors|<p>MIB: IF-MIB</p><p>For packet-oriented interfaces, the number of inbound packets that contained errors preventing them from being deliverable to a higher-layer protocol. For character-oriented or fixed-length interfaces, the number of inbound transmission units that contained errors preventing them from being deliverable to a higher-layer protocol. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime.</p>|SNMP agent|net.if.in.errors[ifInErrors.{#SNMPINDEX}]<p>**Preprocessing**</p><ul><li>Change per second</li></ul>|
|Interface {#IFNAME}({#IFALIAS}): Outbound packets with errors|<p>MIB: IF-MIB</p><p>For packet-oriented interfaces, the number of outbound packets that contained errors preventing them from being deliverable to a higher-layer protocol. For character-oriented or fixed-length interfaces, the number of outbound transmission units that contained errors preventing them from being deliverable to a higher-layer protocol. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime.</p>|SNMP agent|net.if.out.errors[ifOutErrors.{#SNMPINDEX}]<p>**Preprocessing**</p><ul><li>Change per second</li></ul>|
|Interface {#IFNAME}({#IFALIAS}): Outbound packets discarded|<p>MIB: IF-MIB</p><p>The number of outbound packets which were chosen to be discarded</p><p>even though no errors had been detected to prevent their being deliverable to a higher-layer protocol.</p><p>One possible reason for discarding such a packet could be to free up buffer space.</p><p>Discontinuities in the value of this counter can occur at re-initialization of the management system,</p><p>and at other times as indicated by the value of ifCounterDiscontinuityTime.</p>|SNMP agent|net.if.out.discards[ifOutDiscards.{#SNMPINDEX}]<p>**Preprocessing**</p><ul><li>Change per second</li></ul>|
|Interface {#IFNAME}({#IFALIAS}): Inbound packets discarded|<p>MIB: IF-MIB</p><p>The number of inbound packets which were chosen to be discarded</p><p>even though no errors had been detected to prevent their being deliverable to a higher-layer protocol.</p><p>One possible reason for discarding such a packet could be to free up buffer space.</p><p>Discontinuities in the value of this counter can occur at re-initialization of the management system,</p><p>and at other times as indicated by the value of ifCounterDiscontinuityTime.</p>|SNMP agent|net.if.in.discards[ifInDiscards.{#SNMPINDEX}]<p>**Preprocessing**</p><ul><li>Change per second</li></ul>|
|Interface {#IFNAME}({#IFALIAS}): Interface type|<p>MIB: IF-MIB</p><p>The type of interface.</p><p>Additional values for ifType are assigned by the Internet Assigned Numbers Authority (IANA),</p><p>through updating the syntax of the IANAifType textual convention.</p>|SNMP agent|net.if.type[ifType.{#SNMPINDEX}]<p>**Preprocessing**</p><ul><li><p>Discard unchanged with heartbeat: `1d`</p></li></ul>|
|Interface {#IFNAME}({#IFALIAS}): Speed|<p>MIB: IF-MIB</p><p>An estimate of the interface's current bandwidth in units of 1,000,000 bits per second. If this object reports a value of `n' then the speed of the interface is somewhere in the range of `n-500,000' to`n+499,999'. For interfaces which do not vary in bandwidth or for those where no accurate estimation can be made, this object should contain the nominal bandwidth. For a sub-layer which has no concept of bandwidth, this object should be zero.</p>|SNMP agent|net.if.speed[ifHighSpeed.{#SNMPINDEX}]<p>**Preprocessing**</p><ul><li><p>Custom multiplier: `1000000`</p></li><li><p>Discard unchanged with heartbeat: `1h`</p></li></ul>|
### Trigger prototypes for Network interfaces discovery
|Name|Description|Expression|Severity|Dependencies and additional info|
|----|-----------|----------|--------|--------------------------------|
|Interface {#IFNAME}({#IFALIAS}): Link down|<p>This trigger expression works as follows:<br>1. It can be triggered if the operations status is down.<br>2. `{$IFCONTROL:"{#IFNAME}"}=1` - a user can redefine context macro to value - 0. That marks this interface as not important. No new trigger will be fired if this interface is down.<br>3. `{TEMPLATE_NAME:METRIC.diff()}=1` - the trigger fires only if the operational status was up to (1) sometime before (so, do not fire for the 'eternal off' interfaces.)<br><br>WARNING: if closed manually - it will not fire again on the next poll, because of .diff.</p>|`{$IFCONTROL:"{#IFNAME}"}=1 and last(/Extreme EXOS by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/Extreme EXOS by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/Extreme EXOS by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#2))`|Average|**Manual close**: Yes|
|Interface {#IFNAME}({#IFALIAS}): High bandwidth usage|<p>The utilization of the network interface is close to its estimated maximum bandwidth.</p>|`(avg(/Extreme EXOS by SNMP/net.if.in[ifHCInOctets.{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Extreme EXOS by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}]) or avg(/Extreme EXOS by SNMP/net.if.out[ifHCOutOctets.{#SNMPINDEX}],15m)>({$IF.UTIL.MAX:"{#IFNAME}"}/100)*last(/Extreme EXOS by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])) and last(/Extreme EXOS by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0`|Warning|**Manual close**: Yes<br>**Depends on**:<br><ul><li>Interface {#IFNAME}({#IFALIAS}): Link down</li></ul>|
|Interface {#IFNAME}({#IFALIAS}): High error rate|<p>It recovers when it is below 80% of the `{$IF.ERRORS.WARN:"{#IFNAME}"}` threshold.</p>|`min(/Extreme EXOS by SNMP/net.if.in.errors[ifInErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"} or min(/Extreme EXOS by SNMP/net.if.out.errors[ifOutErrors.{#SNMPINDEX}],5m)>{$IF.ERRORS.WARN:"{#IFNAME}"}`|Warning|**Manual close**: Yes<br>**Depends on**:<br><ul><li>Interface {#IFNAME}({#IFALIAS}): Link down</li></ul>|
|Interface {#IFNAME}({#IFALIAS}): Ethernet has changed to lower speed than it was before|<p>This Ethernet connection has transitioned down from its known maximum speed. This might be a sign of autonegotiation issues. Acknowledge to close the problem manually.</p>|`change(/Extreme EXOS by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])<0 and last(/Extreme EXOS by SNMP/net.if.speed[ifHighSpeed.{#SNMPINDEX}])>0 and ( last(/Extreme EXOS by SNMP/net.if.type[ifType.{#SNMPINDEX}])=6 or last(/Extreme EXOS by SNMP/net.if.type[ifType.{#SNMPINDEX}])=7 or last(/Extreme EXOS by SNMP/net.if.type[ifType.{#SNMPINDEX}])=11 or last(/Extreme EXOS by SNMP/net.if.type[ifType.{#SNMPINDEX}])=62 or last(/Extreme EXOS by SNMP/net.if.type[ifType.{#SNMPINDEX}])=69 or last(/Extreme EXOS by SNMP/net.if.type[ifType.{#SNMPINDEX}])=117 ) and (last(/Extreme EXOS by SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])<>2)`|Info|**Manual close**: Yes<br>**Depends on**:<br><ul><li>Interface {#IFNAME}({#IFALIAS}): Link down</li></ul>|
### LLD rule EtherLike-MIB Discovery
|Name|Description|Type|Key and additional info|
|----|-----------|----|-----------------------|
|EtherLike-MIB Discovery|<p>Discovering interfaces from IF-MIB and EtherLike-MIB. Interfaces with up(1) Operational Status are discovered.</p>|SNMP agent|net.if.duplex.discovery<p>**Preprocessing**</p><ul><li><p>JavaScript: `The text is too long. Please see the template.`</p></li></ul>|
### Item prototypes for EtherLike-MIB Discovery
|Name|Description|Type|Key and additional info|
|----|-----------|----|-----------------------|
|Interface {#IFNAME}({#IFALIAS}): Duplex status|<p>MIB: EtherLike-MIB</p><p>The current mode of operation of the MAC</p><p>entity. 'unknown' indicates that the current</p><p>duplex mode could not be determined.</p><p></p><p>Management control of the duplex mode is</p><p>accomplished through the MAU MIB. When</p><p>an interface does not support autonegotiation,</p><p>or when autonegotiation is not enabled, the</p><p>duplex mode is controlled using</p><p>ifMauDefaultType. When autonegotiation is</p><p>supported and enabled, duplex mode is controlled</p><p>using ifMauAutoNegAdvertisedBits. In either</p><p>case, the currently operating duplex mode is</p><p>reflected both in this object and in ifMauType.</p><p></p><p>Note that this object provides redundant</p><p>information with ifMauType. Normally, redundant</p><p>objects are discouraged. However, in this</p><p>instance, it allows a management application to</p><p>determine the duplex status of an interface</p><p>without having to know every possible value of</p><p>ifMauType. This was felt to be sufficiently</p><p>valuable to justify the redundancy.</p><p>Reference: [IEEE 802.3 Std.], 30.3.1.1.32,aDuplexStatus.</p>|SNMP agent|net.if.duplex[dot3StatsDuplexStatus.{#SNMPINDEX}]|
### Trigger prototypes for EtherLike-MIB Discovery
|Name|Description|Expression|Severity|Dependencies and additional info|
|----|-----------|----------|--------|--------------------------------|
|Interface {#IFNAME}({#IFALIAS}): In half-duplex mode|<p>Please check autonegotiation settings and cabling</p>|`last(/Extreme EXOS by SNMP/net.if.duplex[dot3StatsDuplexStatus.{#SNMPINDEX}])=2`|Warning|**Manual close**: Yes|
## Feedback
Please report any issues with the template at [`https://support.zabbix.com`](https://support.zabbix.com)
You can also provide feedback, discuss the template, or ask for help at [`ZABBIX forums`](https://www.zabbix.com/forum/zabbix-suggestions-and-feedback)