You can not select more than 25 topics Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.

32 KiB

Dell iDRAC by SNMP

Overview

for Dell servers with iDRAC controllers http://www.dell.com/support/manuals/us/en/19/dell-openmanage-server-administrator-v8.3/snmp_idrac8/idrac-mib?guid=guid-e686536d-bc8e-4e09-8e8b-de8eb052efee Supported systems: http://www.dell.com/support/manuals/us/en/04/dell-openmanage-server-administrator-v8.3/snmp_idrac8/supported-systems?guid=guid-f72b75ba-e686-4e8a-b8c5-ca11c7c21381

Requirements

Zabbix version: 7.0 and higher.

Tested versions

This template has been tested on:

  • iDRAC7, PowerEdge R620
  • iDRAC8, PowerEdge R730xd
  • iDRAC8, PowerEdge R720

Configuration

Zabbix should be configured according to the instructions in the Templates out of the box section.

Setup

Refer to the vendor documentation.

Macros used

Name Description Default
{$TEMP_WARN:"CPU"} 70
{$TEMP_WARN:"Ambient"} 30
{$TEMP_CRIT:"CPU"} 75
{$TEMP_CRIT:"Ambient"} 35
{$DISK_ARRAY_WARN_STATUS:"nonCritical"} 4
{$DISK_ARRAY_CRIT_STATUS:"critical"} 5
{$DISK_ARRAY_FAIL_STATUS:"nonRecoverable"} 6
{$DISK_ARRAY_CACHE_BATTERY_CRIT_STATUS} 3
{$DISK_ARRAY_CACHE_BATTERY_WARN_STATUS} 4
{$DISK_ARRAY_CACHE_BATTERY_OK_STATUS} 2
{$DISK_WARN_STATUS:"nonCritical"} 4
{$DISK_FAIL_STATUS:"critical"} 5
{$DISK_FAIL_STATUS:"nonRecoverable"} 6
{$DISK_SMART_FAIL_STATUS} 1
{$VDISK_CRIT_STATUS:"failed"} 3
{$VDISK_WARN_STATUS:"degraded"} 4
{$HEALTH_DISASTER_STATUS} 6
{$HEALTH_CRIT_STATUS} 5
{$HEALTH_WARN_STATUS} 4
{$TEMP_WARN_STATUS} 4
{$TEMP_CRIT_STATUS} 5
{$TEMP_DISASTER_STATUS} 6
{$FAN_WARN_STATUS:"nonCriticalUpper"} 4
{$FAN_WARN_STATUS:"nonCriticalLower"} 7
{$FAN_CRIT_STATUS:"criticalUpper"} 5
{$FAN_CRIT_STATUS:"nonRecoverableUpper"} 6
{$FAN_CRIT_STATUS:"criticalLower"} 8
{$FAN_CRIT_STATUS:"nonRecoverableLower"} 9
{$FAN_CRIT_STATUS:"failed"} 10
{$PSU_WARN_STATUS:"nonCritical"} 4
{$PSU_CRIT_STATUS:"critical"} 5
{$PSU_CRIT_STATUS:"nonRecoverable"} 6
{$TEMP_CRIT} 60
{$TEMP_CRIT_LOW} 5
{$TEMP_WARN} 50
{$SNMP.TIMEOUT} 5m
{$ICMP_LOSS_WARN} 20
{$ICMP_RESPONSE_TIME_WARN} 0.15

Items

Name Description Type Key and additional info
Dell iDRAC: Overall system health status

MIB: IDRAC-MIB-SMIv2

This attribute defines the overall rollup status of all components in the system being monitored by the remote access card. Includes system, storage, IO devices, iDRAC, CPU, memory, etc.

SNMP agent system.status[globalSystemStatus.0]
Dell iDRAC: Hardware model name

MIB: IDRAC-MIB-SMIv2

This attribute defines the model name of the system.

SNMP agent system.hw.model

Preprocessing

  • Discard unchanged with heartbeat: 1d

Dell iDRAC: Operating system

MIB: IDRAC-MIB-SMIv2

This attribute defines the name of the operating system that the hostis running.

SNMP agent system.sw.os[systemOSName]

Preprocessing

  • Discard unchanged with heartbeat: 1d

Dell iDRAC: Hardware serial number

MIB: IDRAC-MIB-SMIv2

This attribute defines the service tag of the system.

SNMP agent system.hw.serialnumber

Preprocessing

  • Discard unchanged with heartbeat: 1d

Dell iDRAC: Firmware version

MIB: IDRAC-MIB-SMIv2

This attribute defines the firmware version of a remote access card.

SNMP agent system.hw.firmware

Preprocessing

  • Discard unchanged with heartbeat: 1d

Dell iDRAC: Uptime (network)

MIB: SNMPv2-MIB

The time (in hundredths of a second) since the network management portion of the system was last re-initialized.

SNMP agent system.net.uptime[sysUpTime.0]

Preprocessing

  • Custom multiplier: 0.01

Dell iDRAC: Uptime (hardware)

MIB: HOST-RESOURCES-MIB

The amount of time since this host was last initialized. Note that this is different from sysUpTime in the SNMPv2-MIB [RFC1907] because sysUpTime is the uptime of the network management portion of the system.

SNMP agent system.hw.uptime[hrSystemUptime.0]

Preprocessing

  • Check for not supported value

    Custom on fail: Set value to: 0

  • Custom multiplier: 0.01

Dell iDRAC: SNMP traps (fallback)

The item is used to collect all SNMP traps unmatched by other snmptrap items

SNMP trap snmptrap.fallback
Dell iDRAC: System location

MIB: SNMPv2-MIB

The physical location of this node (e.g., `telephone closet, 3rd floor'). If the location is unknown, the value is the zero-length string.

SNMP agent system.location[sysLocation.0]

Preprocessing

  • Discard unchanged with heartbeat: 12h

Dell iDRAC: System contact details

MIB: SNMPv2-MIB

The textual identification of the contact person for this managed node, together with information on how to contact this person. If no contact information is known, the value is the zero-length string.

SNMP agent system.contact[sysContact.0]

Preprocessing

  • Discard unchanged with heartbeat: 12h

Dell iDRAC: System object ID

MIB: SNMPv2-MIB

The vendor's authoritative identification of the network management subsystem contained in the entity. This value is allocated within the SMI enterprises subtree (1.3.6.1.4.1) and provides an easy and unambiguous means for determiningwhat kind of box' is being managed. For example, if vendorFlintstones, Inc.' was assigned the subtree1.3.6.1.4.1.4242, it could assign the identifier 1.3.6.1.4.1.4242.1.1 to its `Fred Router'.

SNMP agent system.objectid[sysObjectID.0]

Preprocessing

  • Discard unchanged with heartbeat: 12h

Dell iDRAC: System name

MIB: SNMPv2-MIB

An administratively-assigned name for this managed node.By convention, this is the node's fully-qualified domain name. If the name is unknown, the value is the zero-length string.

SNMP agent system.name

Preprocessing

  • Discard unchanged with heartbeat: 12h

Dell iDRAC: System description

MIB: SNMPv2-MIB

A textual description of the entity. This value should

include the full name and version identification of the system's hardware type, software operating-system, and

networking software.

SNMP agent system.descr[sysDescr.0]

Preprocessing

  • Discard unchanged with heartbeat: 12h

Dell iDRAC: SNMP agent availability

Availability of SNMP checks on the host. The value of this item corresponds to availability icons in the host list.

Possible value:

0 - not available

1 - available

2 - unknown

Zabbix internal zabbix[host,snmp,available]
Dell iDRAC: ICMP ping Simple check icmpping
Dell iDRAC: ICMP loss Simple check icmppingloss
Dell iDRAC: ICMP response time Simple check icmppingsec

Triggers

Name Description Expression Severity Dependencies and additional info
Dell iDRAC: System is in unrecoverable state!

Please check the device for faults

count(/Dell iDRAC by SNMP/system.status[globalSystemStatus.0],#1,"eq","{$HEALTH_DISASTER_STATUS}")=1 High
Dell iDRAC: System status is in critical state

Please check the device for errors

count(/Dell iDRAC by SNMP/system.status[globalSystemStatus.0],#1,"eq","{$HEALTH_CRIT_STATUS}")=1 High Depends on:
  • Dell iDRAC: System is in unrecoverable state!
Dell iDRAC: System status is in warning state

Please check the device for warnings

count(/Dell iDRAC by SNMP/system.status[globalSystemStatus.0],#1,"eq","{$HEALTH_WARN_STATUS}")=1 Warning Depends on:
  • Dell iDRAC: System is in unrecoverable state!
  • Dell iDRAC: System status is in critical state
Dell iDRAC: Operating system description has changed

Operating system description has changed. Possible reasons that system has been updated or replaced. Acknowledge to close the problem manually.

last(/Dell iDRAC by SNMP/system.sw.os[systemOSName],#1)<>last(/Dell iDRAC by SNMP/system.sw.os[systemOSName],#2) and length(last(/Dell iDRAC by SNMP/system.sw.os[systemOSName]))>0 Info Manual close: Yes
Depends on:
  • Dell iDRAC: System name has changed
Dell iDRAC: Device has been replaced

Device serial number has changed. Acknowledge to close the problem manually.

last(/Dell iDRAC by SNMP/system.hw.serialnumber,#1)<>last(/Dell iDRAC by SNMP/system.hw.serialnumber,#2) and length(last(/Dell iDRAC by SNMP/system.hw.serialnumber))>0 Info Manual close: Yes
Dell iDRAC: Firmware has changed

Firmware version has changed. Acknowledge to close the problem manually.

last(/Dell iDRAC by SNMP/system.hw.firmware,#1)<>last(/Dell iDRAC by SNMP/system.hw.firmware,#2) and length(last(/Dell iDRAC by SNMP/system.hw.firmware))>0 Info Manual close: Yes
Dell iDRAC: Host has been restarted

Uptime is less than 10 minutes.

(last(/Dell iDRAC by SNMP/system.hw.uptime[hrSystemUptime.0])>0 and last(/Dell iDRAC by SNMP/system.hw.uptime[hrSystemUptime.0])<10m) or (last(/Dell iDRAC by SNMP/system.hw.uptime[hrSystemUptime.0])=0 and last(/Dell iDRAC by SNMP/system.net.uptime[sysUpTime.0])<10m) Warning Manual close: Yes
Depends on:
  • Dell iDRAC: No SNMP data collection
Dell iDRAC: System name has changed

The name of the system has changed. Acknowledge to close the problem manually.

last(/Dell iDRAC by SNMP/system.name,#1)<>last(/Dell iDRAC by SNMP/system.name,#2) and length(last(/Dell iDRAC by SNMP/system.name))>0 Info Manual close: Yes
Dell iDRAC: No SNMP data collection

SNMP is not available for polling. Please check device connectivity and SNMP settings.

max(/Dell iDRAC by SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0 Warning Depends on:
  • Dell iDRAC: Unavailable by ICMP ping
Dell iDRAC: Unavailable by ICMP ping

Last three attempts returned timeout. Please check device connectivity.

max(/Dell iDRAC by SNMP/icmpping,#3)=0 High
Dell iDRAC: High ICMP ping loss min(/Dell iDRAC by SNMP/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/Dell iDRAC by SNMP/icmppingloss,5m)<100 Warning Depends on:
  • Dell iDRAC: Unavailable by ICMP ping
Dell iDRAC: High ICMP ping response time avg(/Dell iDRAC by SNMP/icmppingsec,5m)>{$ICMP_RESPONSE_TIME_WARN} Warning Depends on:
  • Dell iDRAC: High ICMP ping loss
  • Dell iDRAC: Unavailable by ICMP ping

LLD rule Temperature CPU Discovery

Name Description Type Key and additional info
Temperature CPU Discovery

Scanning table of Temperature Probe Table IDRAC-MIB-SMIv2::temperatureProbeTable

SNMP agent temp.cpu.discovery

Item prototypes for Temperature CPU Discovery

Name Description Type Key and additional info
{#SENSOR_LOCALE}: Temperature

MIB: IDRAC-MIB-SMIv2

0700.0020.0001.0006 This attribute defines the reading for a temperature probe of type other than temperatureProbeTypeIsDiscrete. When the value for temperatureProbeType is other than temperatureProbeTypeIsDiscrete,the value returned for this attribute is the temperature that the probeis reading in tenths of degrees Centigrade. When the value for temperatureProbeType is temperatureProbeTypeIsDiscrete, a value is not returned for this attribute.

SNMP agent sensor.temp.value[temperatureProbeReading.CPU.{#SNMPINDEX}]

Preprocessing

  • Custom multiplier: 0.1

{#SENSOR_LOCALE}: Temperature status

MIB: IDRAC-MIB-SMIv2

0700.0020.0001.0005 This attribute defines the probe status of the temperature probe.

SNMP agent sensor.temp.status[temperatureProbeStatus.CPU.{#SNMPINDEX}]

Trigger prototypes for Temperature CPU Discovery

Name Description Expression Severity Dependencies and additional info
{#SENSOR_LOCALE}: Temperature is above warning threshold

This trigger uses temperature sensor values as well as temperature sensor status if available

avg(/Dell iDRAC by SNMP/sensor.temp.value[temperatureProbeReading.CPU.{#SNMPINDEX}],5m)>{$TEMP_WARN:"CPU"} or last(/Dell iDRAC by SNMP/sensor.temp.status[temperatureProbeStatus.CPU.{#SNMPINDEX}])={$TEMP_WARN_STATUS} Warning Depends on:
  • {#SENSOR_LOCALE}: Temperature is above critical threshold
{#SENSOR_LOCALE}: Temperature is above critical threshold

This trigger uses temperature sensor values as well as temperature sensor status if available

avg(/Dell iDRAC by SNMP/sensor.temp.value[temperatureProbeReading.CPU.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"CPU"} or last(/Dell iDRAC by SNMP/sensor.temp.status[temperatureProbeStatus.CPU.{#SNMPINDEX}])={$TEMP_CRIT_STATUS} or last(/Dell iDRAC by SNMP/sensor.temp.status[temperatureProbeStatus.CPU.{#SNMPINDEX}])={$TEMP_DISASTER_STATUS} High
{#SENSOR_LOCALE}: Temperature is too low avg(/Dell iDRAC by SNMP/sensor.temp.value[temperatureProbeReading.CPU.{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:"CPU"} Average

LLD rule Temperature Ambient Discovery

Name Description Type Key and additional info
Temperature Ambient Discovery

Scanning table of Temperature Probe Table IDRAC-MIB-SMIv2::temperatureProbeTable

SNMP agent temp.ambient.discovery

Item prototypes for Temperature Ambient Discovery

Name Description Type Key and additional info
{#SENSOR_LOCALE}: Temperature

MIB: IDRAC-MIB-SMIv2

0700.0020.0001.0006 This attribute defines the reading for a temperature probe of type other than temperatureProbeTypeIsDiscrete. When the value for temperatureProbeType is other than temperatureProbeTypeIsDiscrete,the value returned for this attribute is the temperature that the probeis reading in tenths of degrees Centigrade. When the value for temperatureProbeType is temperatureProbeTypeIsDiscrete, a value is not returned for this attribute.

SNMP agent sensor.temp.value[temperatureProbeReading.Ambient.{#SNMPINDEX}]

Preprocessing

  • Custom multiplier: 0.1

{#SENSOR_LOCALE}: Temperature status

MIB: IDRAC-MIB-SMIv2

0700.0020.0001.0005 This attribute defines the probe status of the temperature probe.

SNMP agent sensor.temp.status[temperatureProbeStatus.Ambient.{#SNMPINDEX}]

Trigger prototypes for Temperature Ambient Discovery

Name Description Expression Severity Dependencies and additional info
{#SENSOR_LOCALE}: Temperature is above warning threshold

This trigger uses temperature sensor values as well as temperature sensor status if available

avg(/Dell iDRAC by SNMP/sensor.temp.value[temperatureProbeReading.Ambient.{#SNMPINDEX}],5m)>{$TEMP_WARN:"Ambient"} or last(/Dell iDRAC by SNMP/sensor.temp.status[temperatureProbeStatus.Ambient.{#SNMPINDEX}])={$TEMP_WARN_STATUS} Warning Depends on:
  • {#SENSOR_LOCALE}: Temperature is above critical threshold
{#SENSOR_LOCALE}: Temperature is above critical threshold

This trigger uses temperature sensor values as well as temperature sensor status if available

avg(/Dell iDRAC by SNMP/sensor.temp.value[temperatureProbeReading.Ambient.{#SNMPINDEX}],5m)>{$TEMP_CRIT:"Ambient"} or last(/Dell iDRAC by SNMP/sensor.temp.status[temperatureProbeStatus.Ambient.{#SNMPINDEX}])={$TEMP_CRIT_STATUS} or last(/Dell iDRAC by SNMP/sensor.temp.status[temperatureProbeStatus.Ambient.{#SNMPINDEX}])={$TEMP_DISASTER_STATUS} High
{#SENSOR_LOCALE}: Temperature is too low avg(/Dell iDRAC by SNMP/sensor.temp.value[temperatureProbeReading.Ambient.{#SNMPINDEX}],5m)<{$TEMP_CRIT_LOW:"Ambient"} Average

LLD rule PSU Discovery

Name Description Type Key and additional info
PSU Discovery

IDRAC-MIB-SMIv2::powerSupplyTable

SNMP agent psu.discovery

Item prototypes for PSU Discovery

Name Description Type Key and additional info
{#PSU_DESCR}: Power supply status

MIB: IDRAC-MIB-SMIv2

0600.0012.0001.0005 This attribute defines the status of the power supply.

SNMP agent sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}]

Trigger prototypes for PSU Discovery

Name Description Expression Severity Dependencies and additional info
{#PSU_DESCR}: Power supply is in critical state

Please check the power supply unit for errors

count(/Dell iDRAC by SNMP/sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS:\"critical\"}")=1 or count(/Dell iDRAC by SNMP/sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS:\"nonRecoverable\"}")=1 Average
{#PSU_DESCR}: Power supply is in warning state

Please check the power supply unit for errors

count(/Dell iDRAC by SNMP/sensor.psu.status[powerSupplyStatus.{#SNMPINDEX}],#1,"eq","{$PSU_WARN_STATUS:\"nonCritical\"}")=1 Warning Depends on:
  • {#PSU_DESCR}: Power supply is in critical state

LLD rule FAN Discovery

Name Description Type Key and additional info
FAN Discovery

IDRAC-MIB-SMIv2::coolingDeviceTable

SNMP agent fan.discovery

Item prototypes for FAN Discovery

Name Description Type Key and additional info
{#FAN_DESCR}: Fan status

MIB: IDRAC-MIB-SMIv2

0700.0012.0001.0005 This attribute defines the probe status of the cooling device.

SNMP agent sensor.fan.status[coolingDeviceStatus.{#SNMPINDEX}]
{#FAN_DESCR}: Fan speed

MIB: IDRAC-MIB-SMIv2

0700.0012.0001.0006 This attribute defines the reading for a cooling device

of subtype other than coolingDeviceSubTypeIsDiscrete. When the value

for coolingDeviceSubType is other than coolingDeviceSubTypeIsDiscrete, the

value returned for this attribute is the speed in RPM or the OFF/ON value

of the cooling device. When the value for coolingDeviceSubType is

coolingDeviceSubTypeIsDiscrete, a value is not returned for this attribute.

SNMP agent sensor.fan.speed[coolingDeviceReading.{#SNMPINDEX}]

Trigger prototypes for FAN Discovery

Name Description Expression Severity Dependencies and additional info
{#FAN_DESCR}: Fan is in critical state

Please check the fan unit

count(/Dell iDRAC by SNMP/sensor.fan.status[coolingDeviceStatus.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS:\"criticalUpper\"}")=1 or count(/Dell iDRAC by SNMP/sensor.fan.status[coolingDeviceStatus.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS:\"nonRecoverableUpper\"}")=1 or count(/Dell iDRAC by SNMP/sensor.fan.status[coolingDeviceStatus.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS:\"criticalLower\"}")=1 or count(/Dell iDRAC by SNMP/sensor.fan.status[coolingDeviceStatus.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS:\"nonRecoverableLower\"}")=1 or count(/Dell iDRAC by SNMP/sensor.fan.status[coolingDeviceStatus.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS:\"failed\"}")=1 Average
{#FAN_DESCR}: Fan is in warning state

Please check the fan unit

count(/Dell iDRAC by SNMP/sensor.fan.status[coolingDeviceStatus.{#SNMPINDEX}],#1,"eq","{$FAN_WARN_STATUS:\"nonCriticalUpper\"}")=1 or count(/Dell iDRAC by SNMP/sensor.fan.status[coolingDeviceStatus.{#SNMPINDEX}],#1,"eq","{$FAN_WARN_STATUS:\"nonCriticalLower\"}")=1 Warning Depends on:
  • {#FAN_DESCR}: Fan is in critical state

LLD rule Physical Disk Discovery

Name Description Type Key and additional info
Physical Disk Discovery

IDRAC-MIB-SMIv2::physicalDiskTable

SNMP agent physicaldisk.discovery

Item prototypes for Physical Disk Discovery

Name Description Type Key and additional info
{#DISK_NAME}: Physical disk status

MIB: IDRAC-MIB-SMIv2

The status of the physical disk itself without the propagation of any contained component status.

Possible values:

1: Other

2: Unknown

3: OK

4: Non-critical

5: Critical

6: Non-recoverable

SNMP agent system.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}]
{#DISK_NAME}: Physical disk serial number

MIB: IDRAC-MIB-SMIv2

The physical disk's unique identification number from the manufacturer.

SNMP agent system.hw.physicaldisk.serialnumber[physicalDiskSerialNo.{#SNMPINDEX}]
{#DISK_NAME}: Physical disk S.M.A.R.T. status

MIB: IDRAC-MIB-SMIv2

Indicates whether the physical disk has received a predictive failure alert.

SNMP agent system.hw.physicaldisk.smart_status[physicalDiskSmartAlertIndication.{#SNMPINDEX}]
{#DISK_NAME}: Physical disk model name

MIB: IDRAC-MIB-SMIv2

The model number of the physical disk.

SNMP agent system.hw.physicaldisk.model[physicalDiskProductID.{#SNMPINDEX}]
{#DISK_NAME}: Physical disk part number

MIB: IDRAC-MIB-SMIv2

The part number of the disk.

SNMP agent system.hw.physicaldisk.part_number[physicalDiskPartNumber.{#SNMPINDEX}]
{#DISK_NAME}: Physical disk media type

MIB: IDRAC-MIB-SMIv2

The media type of the physical disk. Possible Values:

1: The media type could not be determined.

2: Hard Disk Drive (HDD).

3: Solid State Drive (SSD).

SNMP agent system.hw.physicaldisk.media_type[physicalDiskMediaType.{#SNMPINDEX}]
{#DISK_NAME}: Disk size

MIB: IDRAC-MIB-SMIv2

The size of the physical disk in megabytes.

SNMP agent system.hw.physicaldisk.size[physicalDiskCapacityInMB.{#SNMPINDEX}]

Preprocessing

  • Custom multiplier: 1048576

Trigger prototypes for Physical Disk Discovery

Name Description Expression Severity Dependencies and additional info
{#DISK_NAME}: Physical disk failed

Please check physical disk for warnings or errors

count(/Dell iDRAC by SNMP/system.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}],#1,"eq","{$DISK_FAIL_STATUS:\"critical\"}")=1 or count(/Dell iDRAC by SNMP/system.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}],#1,"eq","{$DISK_FAIL_STATUS:\"nonRecoverable\"}")=1 High
{#DISK_NAME}: Physical disk is in warning state

Please check physical disk for warnings or errors

count(/Dell iDRAC by SNMP/system.hw.physicaldisk.status[physicalDiskComponentStatus.{#SNMPINDEX}],#1,"eq","{$DISK_WARN_STATUS:\"nonCritical\"}")=1 Warning Depends on:
  • {#DISK_NAME}: Physical disk failed
{#DISK_NAME}: Disk has been replaced

Disk serial number has changed. Acknowledge to close the problem manually.

last(/Dell iDRAC by SNMP/system.hw.physicaldisk.serialnumber[physicalDiskSerialNo.{#SNMPINDEX}],#1)<>last(/Dell iDRAC by SNMP/system.hw.physicaldisk.serialnumber[physicalDiskSerialNo.{#SNMPINDEX}],#2) and length(last(/Dell iDRAC by SNMP/system.hw.physicaldisk.serialnumber[physicalDiskSerialNo.{#SNMPINDEX}]))>0 Info Manual close: Yes
{#DISK_NAME}: Physical disk S.M.A.R.T. failed

Disk probably requires replacement.

count(/Dell iDRAC by SNMP/system.hw.physicaldisk.smart_status[physicalDiskSmartAlertIndication.{#SNMPINDEX}],#1,"eq","{$DISK_SMART_FAIL_STATUS}")=1 High Depends on:
  • {#DISK_NAME}: Physical disk failed

LLD rule Virtual Disk Discovery

Name Description Type Key and additional info
Virtual Disk Discovery

IDRAC-MIB-SMIv2::virtualDiskTable

SNMP agent virtualdisk.discovery

Item prototypes for Virtual Disk Discovery

Name Description Type Key and additional info
Disk {#SNMPVALUE}({#DISK_NAME}): Layout type

MIB: IDRAC-MIB-SMIv2

The virtual disk's RAID type.

Possible values:

1: Not one of the following

2: RAID-0

3: RAID-1

4: RAID-5

5: RAID-6

6: RAID-10

7: RAID-50

8: RAID-60

9: Concatenated RAID 1

10: Concatenated RAID 5

SNMP agent system.hw.virtualdisk.layout[virtualDiskLayout.{#SNMPINDEX}]
Disk {#SNMPVALUE}({#DISK_NAME}): Current state

MIB: IDRAC-MIB-SMIv2

The state of the virtual disk when there are progressive operations ongoing.

Possible values:

1: There is no active operation running.

2: The virtual disk configuration has changed. The physical disks included in the virtual disk are being modified to support the new configuration.

3: A Consistency Check (CC) is being performed on the virtual disk.

4: The virtual disk is being initialized.

5: BackGround Initialization (BGI) is being performed on the virtual disk.

SNMP agent system.hw.virtualdisk.state[virtualDiskOperationalState.{#SNMPINDEX}]
Disk {#SNMPVALUE}({#DISK_NAME}): Read policy

MIB: IDRAC-MIB-SMIv2

The read policy used by the controller for read operations on this virtual disk.

Possible values:

1: No Read Ahead.

2: Read Ahead.

3: Adaptive Read Ahead.

SNMP agent system.hw.virtualdisk.readpolicy[virtualDiskReadPolicy.{#SNMPINDEX}]
Disk {#SNMPVALUE}({#DISK_NAME}): Write policy

MIB: IDRAC-MIB-SMIv2

The write policy used by the controller for write operations on this virtual disk.

Possible values:

1: Write Through.

2: Write Back.

3: Force Write Back.

SNMP agent system.hw.virtualdisk.writepolicy[virtualDiskWritePolicy.{#SNMPINDEX}]
Disk {#SNMPVALUE}({#DISK_NAME}): Disk size

MIB: IDRAC-MIB-SMIv2

The size of the virtual disk in megabytes.

SNMP agent system.hw.virtualdisk.size[virtualDiskSizeInMB.{#SNMPINDEX}]

Preprocessing

  • Custom multiplier: 1048576

Disk {#SNMPVALUE}({#DISK_NAME}): Status

MIB: IDRAC-MIB-SMIv2

The current state of this virtual disk (which includes any member physical disks.)

Possible states:

1: The current state could not be determined.

2: The virtual disk is operating normally or optimally.

3: The virtual disk has encountered a failure. The data on disk is lost or is about to be lost.

4: The virtual disk encountered a failure with one or all of the constituent redundant physical disks.

The data on the virtual disk might no longer be fault tolerant.

SNMP agent system.hw.virtualdisk.status[virtualDiskState.{#SNMPINDEX}]

Trigger prototypes for Virtual Disk Discovery

Name Description Expression Severity Dependencies and additional info
Disk {#SNMPVALUE}({#DISK_NAME}): Virtual disk failed

Please check virtual disk for warnings or errors

count(/Dell iDRAC by SNMP/system.hw.virtualdisk.status[virtualDiskState.{#SNMPINDEX}],#1,"eq","{$VDISK_CRIT_STATUS:\"failed\"}")=1 High
Disk {#SNMPVALUE}({#DISK_NAME}): Virtual disk is in warning state

Please check virtual disk for warnings or errors

count(/Dell iDRAC by SNMP/system.hw.virtualdisk.status[virtualDiskState.{#SNMPINDEX}],#1,"eq","{$VDISK_WARN_STATUS:\"degraded\"}")=1 Average Depends on:
  • Disk {#SNMPVALUE}({#DISK_NAME}): Virtual disk failed

LLD rule Array Controller Discovery

Name Description Type Key and additional info
Array Controller Discovery

IDRAC-MIB-SMIv2::controllerTable

SNMP agent physicaldisk.arr.discovery

Item prototypes for Array Controller Discovery

Name Description Type Key and additional info
{#CNTLR_NAME}: Disk array controller status

MIB: IDRAC-MIB-SMIv2

The status of the controller itself without the propagation of any contained component status.

Possible values:

1: Other

2: Unknown

3: OK

4: Non-critical

5: Critical

6: Non-recoverable

SNMP agent system.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}]
{#CNTLR_NAME}: Disk array controller model

MIB: IDRAC-MIB-SMIv2

The controller's name as represented in Storage Management.

SNMP agent system.hw.diskarray.model[controllerName.{#SNMPINDEX}]

Trigger prototypes for Array Controller Discovery

Name Description Expression Severity Dependencies and additional info
{#CNTLR_NAME}: Disk array controller is in unrecoverable state!

Please check the device for faults

count(/Dell iDRAC by SNMP/system.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}],#1,"eq","{$DISK_ARRAY_FAIL_STATUS:\"nonRecoverable\"}")=1 Disaster
{#CNTLR_NAME}: Disk array controller is in critical state

Please check the device for faults

count(/Dell iDRAC by SNMP/system.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}],#1,"eq","{$DISK_ARRAY_CRIT_STATUS:\"critical\"}")=1 High Depends on:
  • {#CNTLR_NAME}: Disk array controller is in unrecoverable state!
{#CNTLR_NAME}: Disk array controller is in warning state

Please check the device for faults

count(/Dell iDRAC by SNMP/system.hw.diskarray.status[controllerComponentStatus.{#SNMPINDEX}],#1,"eq","{$DISK_ARRAY_WARN_STATUS:\"nonCritical\"}")=1 Average Depends on:
  • {#CNTLR_NAME}: Disk array controller is in unrecoverable state!
  • {#CNTLR_NAME}: Disk array controller is in critical state

LLD rule Array Controller Cache Discovery

Name Description Type Key and additional info
Array Controller Cache Discovery

IDRAC-MIB-SMIv2::batteryTable

SNMP agent array.cache.discovery

Item prototypes for Array Controller Cache Discovery

Name Description Type Key and additional info
Battery {#BATTERY_NUM}: Disk array cache controller battery status

MIB: IDRAC-MIB-SMIv2

Current state of battery.

Possible values:

1: The current state could not be determined.

2: The battery is operating normally.

3: The battery has failed and needs to be replaced.

4: The battery temperature is high or charge level is depleting.

5: The battery is missing or not detected.

6: The battery is undergoing the re-charge phase.

7: The battery voltage or charge level is below the threshold.

SNMP agent system.hw.diskarray.cache.battery.status[batteryState.{#SNMPINDEX}]

Trigger prototypes for Array Controller Cache Discovery

Name Description Expression Severity Dependencies and additional info
Battery {#BATTERY_NUM}: Disk array cache controller battery is in warning state

Please check the device for faults

count(/Dell iDRAC by SNMP/system.hw.diskarray.cache.battery.status[batteryState.{#SNMPINDEX}],#1,"eq","{$DISK_ARRAY_CACHE_BATTERY_WARN_STATUS}")=1 Warning Depends on:
  • Battery {#BATTERY_NUM}: Disk array cache controller battery is in critical state!
Battery {#BATTERY_NUM}: Disk array cache controller battery is not in optimal state

Please check the device for faults

count(/Dell iDRAC by SNMP/system.hw.diskarray.cache.battery.status[batteryState.{#SNMPINDEX}],#1,"ne","{$DISK_ARRAY_CACHE_BATTERY_OK_STATUS}")=1 Warning Depends on:
  • Battery {#BATTERY_NUM}: Disk array cache controller battery is in critical state!
  • Battery {#BATTERY_NUM}: Disk array cache controller battery is in warning state
Battery {#BATTERY_NUM}: Disk array cache controller battery is in critical state!

Please check the device for faults

count(/Dell iDRAC by SNMP/system.hw.diskarray.cache.battery.status[batteryState.{#SNMPINDEX}],#1,"eq","{$DISK_ARRAY_CACHE_BATTERY_CRIT_STATUS}")=1 Average

Feedback

Please report any issues with the template at https://support.zabbix.com

You can also provide feedback, discuss the template, or ask for help at ZABBIX forums